新绛KTC1/LWHPull Rod Linear Displacement Sensor 新绛KTC2 Pull Rod Linear Displacement Sensor 新绛KTF Slider Displacement Sensor 新绛KTF1 Slider Displacement Sensor 新绛KPC1 Articulated Electronic Ruler 新绛KPC1H Hersman Plug out Pull-rod Resistance 新绛KPM12R1/KPM12R2 Self-reset Resistance Sensor 新绛KPM16 Shock Travel Sensor 新绛KPM18 Small Articulated Resistance Sensor 新绛KPM22 Small Articulated Resistance Sensor 新绛KPM23 Small Articulated Resistance Sensor 新绛KPM12 Shock Travel Sensor 新绛WY-01 Resistive Displacement Sensor 新绛KSE Pull Rod Displacement Sensor 新绛KSC Square Tube Miniature Self-reset Displacement sensor 新绛KSP Circular Tube Miniature Self-reset 新绛KTR11/12,KTR2 Spring Self-return Position Potentiometer 新绛KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 新绛KSN Self-resetting Displacement Sensor 新绛KFM Micro Slider Type Resistance Sensor 新绛WDL Rod Type Displacement Sensor 新绛KPF Flange Displacement Sensor 新绛KTM Miniature Pull Rod Displacement Sensor 新绛KPFZ Flange-mounted self-resetting resistance ruler 新绛KSD Linear Position Sensor 13FLP 新绛KST Self resetting displacement sensor 新绛KS8X Micro Self-resetting Displacement Sensor 新绛KSE Rod type displacement sensor 新绛KPM9 Mini Type Pull Rod Displacement Sensor 新绛LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 新绛KEP Brushless Sensor with Waterproof and Dustproof 新绛LEP displacement sensorwith Waterproof and dustproof
Rope/wire displ...

more+

新绛WS-S Pull Wire Displacement Sensor 新绛MPS-XL Pull Wire Displacement Sensor 新绛MPS-L Pull Wire Displacement Sensor 新绛MPS-L Magnetic Draw Wire Displacement Sensor 新绛MPSFS2-S Waterproof Absolute Wire Rope Sensor 新绛LPS-M Pull Wire Displacement Sensor 新绛LPS-S Pull Wire Displacement Sensor 新绛MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 新绛MPS-XS Magnetic Mounting Rope Displacement Sensor 新绛MPSFS2-M Waterproof Absolute Wire Rope Sensor 新绛MPS-XXXS Pull Wire Displacement Sensor 新绛MPS-XXS Pull Wire Displacement Sensor 新绛MPS-XS Pull Wire Displacement Sensor 新绛MPS-S Pull Wire Displacement Sensor 新绛MPS-M Pull Wire Displacement Sensor 新绛MDS-S Pull Wire Displacement Sensor 新绛SM-S Pull Wire Displacement Sensor 新绛WEP-S Pull Wire Displacement Sensor 新绛WEP-M Pull Wire Displacement Sensor 新绛SM-M Pull Wire Displacement Sensor 新绛MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 新绛MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 新绛MPSFS2-L Waterproof Absolute Wire Rope Sensor 新绛MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 新绛MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 新绛MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 新绛MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新绛MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新绛MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新绛MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新绛MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新绛MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
Your current location is:Home>>新绛Product>>Digital Indicator>>新绛XSAE Displacement Sensor Digital Display Instrument

新绛XSAE Displacement Sensor Digital Display Instrument

  • Product classification:XSAE Displacement Sensor Digital Display Instrument
  • Number of views:787
  • QR code:
  • Release time:2023-11-14
  • Overview

XSAE Displacement Sensor Digital  Display Instrument

Paired with resistance scale, eddy current displacement sensor, etc. 0.05 level accuracy, measurement and control speed 10 times per second. Display range -19999~45000. Panel keys and switch input zero setting function. 8-segment polyline correction function. Optional 1 to 4 alarm output points. There are five basic alarm modes and five standby alarm modes corresponding to the five basic alarm modes. (Standby alarm mode: means that when the instrument is powered on, it will not alarm even if it is in the alarm area. When the measured value enters the non-alarm area, the standby condition will be established, and then it will alarm normally). 4 optional external power supplies. Optional communication, transmission and printing functions.

■ Connecting with  resistance scale, eddy current displacement sensor, etc.

■ 0.2 level accuracy, measuring and controlling speed can be reached at 10 times per second. Display range -1999~9999

■ Panel button and digital input zero function

■ 8-band polyline correction function

■ Optional can be choosen from  1 to 4 alarm output. Including the upper limit of measurement value, the lower limit of measurement value, the upper limit of deviation, the lower limit of deviation, the absolute value of deviation, five basic alarm modes and five standby alarm modes corresponding to five basic alarm modes

(Standby alarm mode: When the instrument is powered on, it will not alarm even if it is in the alarm area. When the measured value enters the non-alarm area, the standby condition is established, and then the alarm is normal.)

4 optional external power supplies

Optional communication, transmission and printing functions.

 

content

code description

XSAE-

0.05 level measurement accuracy; 10 times per second measurement and control speed

Diemnsion

AH

160×80×125      Hole Size:152×76

CH

96×48×112       Hole Size:92×45

Panel specification


Digit LED

Signal input(Other input signals, instructions when ordering)


I

DC(4-20)mA、(0-10)mA、(0-20)mA

V

DC Voltage(0-5)V、(1-5)V

W

Potentiometer(500Ω~10kΩ

Contact input (optional)

K

1 point external switch input for zeroing.

 Alarm(optional)

T1~4

T3、T4 limit AH   (250V AC/3A,Resistance load)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

External power supply (optional)

(No external power supply is required when the input signal is W (potentiometer)

B1

24V±5% 50mA below

B1G

24V±5% 100mA below

B2

12V±5% 50mA below

B2G

12V±5% 100mA below

Communication (optional)

(communication rate: 2400, 4800, 9600, 19200)

(Address: 0-99)

S1

TC ASCII Protocol RS232

S2

TC ASCII Protocol RS485

M1

Modbus-RTU Protocol RS232

M2

Modbus-RTU Protocol RS485

 Print interface (optional)

P


Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24V AC 50/60 Hz;10-24V DC(limit CH)


  • Application
Prev:no morer