TEL:

180 3818 6775

Announcement:

Product

太原Sensors

more+

Linear Position Sensor

more+

太原KTC11 Pull Rod Linear Displacement Sensor 太原KTC1/LWHPull Rod Linear Displacement Sensor 太原KTF Slider Displacement Sensor 太原KTC2/KTC21 Pull Rod Linear Displacement Sensor 太原KTF1 Slider Displacement Sensor 太原KTR11/12,KTR2 Spring Self-return Position Potentiometer 太原KTM Miniature Pull Rod Displacement Sensor 太原KTR3/KTR4 Spring Self-return Position Potentiometer 太原TR Spring Self-return Position Potentiometer 太原KPC1H Hersman Plug out Pull-rod Resistance 太原KPC1 Articulated Electronic Ruler 太原KPM23 Small Articulated Resistance Sensor 太原KPM22 Small Articulated Resistance Sensor 太原KPM18 Small Articulated Resistance Sensor 太原KPM16 Shock Travel Sensor 太原KPM12 Shock Travel Sensor 太原KPM12R1/KPM12R2 Self-reset Resistance Sensor 太原WY-01 Resistive Displacement Sensor 太原WDL Rod Type Displacement Sensor 太原KSE Pull Rod Displacement Sensor 太原KPF Flange Displacement Sensor 太原KFM Micro Slider Type Resistance Sensor 太原KSP Circular Tube Miniature Self-reset 太原KSC Square Tube Miniature Self-reset Displacement sensor 太原KS8X Micro Self-resetting Displacement Sensor 太原KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 太原KST Self resetting displacement sensor 太原KSD Linear Position Sensor 13FLP 太原KPFZ Flange-mounted self-resetting resistance ruler 太原LEP displacement sensorwith Waterproof and dustproof 太原KEP Brushless Sensor with Waterproof and Dustproof 太原LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 太原KPM9 Mini Type Pull Rod Displacement Sensor 太原KSE Rod type displacement sensor 太原KSF Micro Slide Type Displacement Sensor 太原KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

太原MPS-XXXS Pull Wire Displacement Sensor 太原MPS-XXS Pull Wire Displacement Sensor 太原MPS-XS Pull Wire Displacement Sensor 太原MPS-S Pull Wire Displacement Sensor 太原MPS-M Pull Wire Displacement Sensor 太原MPS-L Pull Wire Displacement Sensor 太原MPS-XL Pull Wire Displacement Sensor 太原MPSFS2-S Waterproof Absolute Wire Rope Sensor 太原MPSFS2-M Waterproof Absolute Wire Rope Sensor 太原MPSFS2-L Waterproof Absolute Wire Rope Sensor 太原MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 太原MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 太原MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 太原MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原SM-S Pull Wire Displacement Sensor 太原SM-M Pull Wire Displacement Sensor 太原WEP-S Pull Wire Displacement Sensor 太原WEP-M Pull Wire Displacement Sensor 太原WS-S Pull Wire Displacement Sensor 太原MDS-S Pull Wire Displacement Sensor 太原MPS-XS Magnetic Mounting Rope Displacement Sensor 太原MPS-L Magnetic Draw Wire Displacement Sensor 太原MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 太原MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 太原MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Magnetostrictive displacement/liquid level sensor

more+

太原Fully Automatic Lubricating Oil Pump

more+

太原Electric Automatic Oil Pump / Manual Oil Pump

more+

太原MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 太原MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 太原MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 太原MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 太原MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 太原MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MGH-1205-100T Semi-automatic Butter Lubrication Pump 太原MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 太原MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 太原MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 太原MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 太原MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 太原MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 太原MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 太原MRH-1202-100T Semi-automatic Grease Lubrication Pump 太原MRH-1232-100TB Automatical Grease Lubrication Pump 太原MGH-1202-100T Semi-automatic Butter Lubrication Pump 太原MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>太原Product>>Digital Indicator>>太原XSK Digital Display Instrument

太原XSK Digital Instrument

  • Product classification:XSK Digital Display Instrument
  • Number of views:1970
  • QR code:
  • Release time:2023-11-14
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)


  • Application
Prev:no morer
Next:no morer