TEL:

180 3818 6775

Announcement:

Product

太原Sensors

more+

Linear Position Sensor

more+

太原KTC11 Pull Rod Linear Displacement Sensor 太原KTC1/LWHPull Rod Linear Displacement Sensor 太原KTF Slider Displacement Sensor 太原KTC2/KTC21 Pull Rod Linear Displacement Sensor 太原KTF1 Slider Displacement Sensor 太原KTR11/12,KTR2 Spring Self-return Position Potentiometer 太原KTM Miniature Pull Rod Displacement Sensor 太原KTR3/KTR4 Spring Self-return Position Potentiometer 太原TR Spring Self-return Position Potentiometer 太原KPC1H Hersman Plug out Pull-rod Resistance 太原KPC1 Articulated Electronic Ruler 太原KPM23 Small Articulated Resistance Sensor 太原KPM22 Small Articulated Resistance Sensor 太原KPM18 Small Articulated Resistance Sensor 太原KPM16 Shock Travel Sensor 太原KPM12 Shock Travel Sensor 太原KPM12R1/KPM12R2 Self-reset Resistance Sensor 太原WY-01 Resistive Displacement Sensor 太原WDL Rod Type Displacement Sensor 太原KSE Pull Rod Displacement Sensor 太原KPF Flange Displacement Sensor 太原KFM Micro Slider Type Resistance Sensor 太原KSP Circular Tube Miniature Self-reset 太原KSC Square Tube Miniature Self-reset Displacement sensor 太原KS8X Micro Self-resetting Displacement Sensor 太原KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 太原KST Self resetting displacement sensor 太原KSD Linear Position Sensor 13FLP 太原KPFZ Flange-mounted self-resetting resistance ruler 太原LEP displacement sensorwith Waterproof and dustproof 太原KEP Brushless Sensor with Waterproof and Dustproof 太原LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 太原KPM9 Mini Type Pull Rod Displacement Sensor 太原KSE Rod type displacement sensor 太原KSF Micro Slide Type Displacement Sensor 太原KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

太原MPS-XXXS Pull Wire Displacement Sensor 太原MPS-XXS Pull Wire Displacement Sensor 太原MPS-XS Pull Wire Displacement Sensor 太原MPS-S Pull Wire Displacement Sensor 太原MPS-M Pull Wire Displacement Sensor 太原MPS-L Pull Wire Displacement Sensor 太原MPS-XL Pull Wire Displacement Sensor 太原MPSFS2-S Waterproof Absolute Wire Rope Sensor 太原MPSFS2-M Waterproof Absolute Wire Rope Sensor 太原MPSFS2-L Waterproof Absolute Wire Rope Sensor 太原MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 太原MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 太原MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 太原MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 太原SM-S Pull Wire Displacement Sensor 太原SM-M Pull Wire Displacement Sensor 太原WEP-S Pull Wire Displacement Sensor 太原WEP-M Pull Wire Displacement Sensor 太原WS-S Pull Wire Displacement Sensor 太原MDS-S Pull Wire Displacement Sensor 太原MPS-XS Magnetic Mounting Rope Displacement Sensor 太原MPS-L Magnetic Draw Wire Displacement Sensor 太原MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 太原MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 太原MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Magnetostrictive displacement/liquid level sensor

more+

太原Fully Automatic Lubricating Oil Pump

more+

太原Electric Automatic Oil Pump / Manual Oil Pump

more+

太原MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 太原MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 太原MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 太原MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 太原MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 太原MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MGH-1205-100T Semi-automatic Butter Lubrication Pump 太原MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 太原MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 太原MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 太原MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 太原MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 太原MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 太原MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 太原MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 太原MRH-1202-100T Semi-automatic Grease Lubrication Pump 太原MRH-1232-100TB Automatical Grease Lubrication Pump 太原MGH-1202-100T Semi-automatic Butter Lubrication Pump 太原MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>太原Product>>Digital Indicator>>太原XSEW Digital Display Instrument

太原XSEW Digital Instrument

  • Product classification:XSEW Digital Display Instrument
  • Number of views:2325
  • QR code:
  • Release time:2023-11-14
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)