TEL:

180 3818 6775

Announcement:

Product

吕梁Sensors

more+

Linear Position Sensor

more+

吕梁KTC11 Pull Rod Linear Displacement Sensor 吕梁KTC1/LWHPull Rod Linear Displacement Sensor 吕梁KTF Slider Displacement Sensor 吕梁KTC2/KTC21 Pull Rod Linear Displacement Sensor 吕梁KTF1 Slider Displacement Sensor 吕梁KTR11/12,KTR2 Spring Self-return Position Potentiometer 吕梁KTM Miniature Pull Rod Displacement Sensor 吕梁KTR3/KTR4 Spring Self-return Position Potentiometer 吕梁TR Spring Self-return Position Potentiometer 吕梁KPC1H Hersman Plug out Pull-rod Resistance 吕梁KPC1 Articulated Electronic Ruler 吕梁KPM23 Small Articulated Resistance Sensor 吕梁KPM22 Small Articulated Resistance Sensor 吕梁KPM18 Small Articulated Resistance Sensor 吕梁KPM16 Shock Travel Sensor 吕梁KPM12 Shock Travel Sensor 吕梁KPM12R1/KPM12R2 Self-reset Resistance Sensor 吕梁WY-01 Resistive Displacement Sensor 吕梁WDL Rod Type Displacement Sensor 吕梁KSE Pull Rod Displacement Sensor 吕梁KPF Flange Displacement Sensor 吕梁KFM Micro Slider Type Resistance Sensor 吕梁KSP Circular Tube Miniature Self-reset 吕梁KSC Square Tube Miniature Self-reset Displacement sensor 吕梁KS8X Micro Self-resetting Displacement Sensor 吕梁KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 吕梁KST Self resetting displacement sensor 吕梁KSD Linear Position Sensor 13FLP 吕梁KPFZ Flange-mounted self-resetting resistance ruler 吕梁LEP displacement sensorwith Waterproof and dustproof 吕梁KEP Brushless Sensor with Waterproof and Dustproof 吕梁LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 吕梁KPM9 Mini Type Pull Rod Displacement Sensor 吕梁KSE Rod type displacement sensor 吕梁KSF Micro Slide Type Displacement Sensor 吕梁KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

吕梁MPS-XXXS Pull Wire Displacement Sensor 吕梁MPS-XXS Pull Wire Displacement Sensor 吕梁MPS-XS Pull Wire Displacement Sensor 吕梁MPS-S Pull Wire Displacement Sensor 吕梁MPS-M Pull Wire Displacement Sensor 吕梁MPS-L Pull Wire Displacement Sensor 吕梁MPS-XL Pull Wire Displacement Sensor 吕梁MPSFS2-S Waterproof Absolute Wire Rope Sensor 吕梁MPSFS2-M Waterproof Absolute Wire Rope Sensor 吕梁MPSFS2-L Waterproof Absolute Wire Rope Sensor 吕梁MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 吕梁MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 吕梁MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 吕梁MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁SM-S Pull Wire Displacement Sensor 吕梁SM-M Pull Wire Displacement Sensor 吕梁WEP-S Pull Wire Displacement Sensor 吕梁WEP-M Pull Wire Displacement Sensor 吕梁WS-S Pull Wire Displacement Sensor 吕梁MDS-S Pull Wire Displacement Sensor 吕梁MPS-XS Magnetic Mounting Rope Displacement Sensor 吕梁MPS-L Magnetic Draw Wire Displacement Sensor 吕梁MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 吕梁MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 吕梁MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Magnetostrictive displacement/liquid level sensor

more+

吕梁Fully Automatic Lubricating Oil Pump

more+

吕梁Electric Automatic Oil Pump / Manual Oil Pump

more+

吕梁MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 吕梁MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 吕梁MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 吕梁MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 吕梁MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 吕梁MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MGH-1205-100T Semi-automatic Butter Lubrication Pump 吕梁MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 吕梁MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 吕梁MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 吕梁MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 吕梁MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 吕梁MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 吕梁MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 吕梁MRH-1202-100T Semi-automatic Grease Lubrication Pump 吕梁MRH-1232-100TB Automatical Grease Lubrication Pump 吕梁MGH-1202-100T Semi-automatic Butter Lubrication Pump 吕梁MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>吕梁Product>>Digital Indicator>>吕梁XSK Digital Display Instrument

吕梁XSK Digital Instrument

  • Product classification:XSK Digital Display Instrument
  • Number of views:1825
  • QR code:
  • Release time:2023-11-14
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)


  • Application