TEL:

180 3818 6775

Announcement:

Product

吕梁Sensors

more+

Linear Position Sensor

more+

吕梁KTC11 Pull Rod Linear Displacement Sensor 吕梁KTC1/LWHPull Rod Linear Displacement Sensor 吕梁KTF Slider Displacement Sensor 吕梁KTC2/KTC21 Pull Rod Linear Displacement Sensor 吕梁KTF1 Slider Displacement Sensor 吕梁KTR11/12,KTR2 Spring Self-return Position Potentiometer 吕梁KTM Miniature Pull Rod Displacement Sensor 吕梁KTR3/KTR4 Spring Self-return Position Potentiometer 吕梁TR Spring Self-return Position Potentiometer 吕梁KPC1H Hersman Plug out Pull-rod Resistance 吕梁KPC1 Articulated Electronic Ruler 吕梁KPM23 Small Articulated Resistance Sensor 吕梁KPM22 Small Articulated Resistance Sensor 吕梁KPM18 Small Articulated Resistance Sensor 吕梁KPM16 Shock Travel Sensor 吕梁KPM12 Shock Travel Sensor 吕梁KPM12R1/KPM12R2 Self-reset Resistance Sensor 吕梁WY-01 Resistive Displacement Sensor 吕梁WDL Rod Type Displacement Sensor 吕梁KSE Pull Rod Displacement Sensor 吕梁KPF Flange Displacement Sensor 吕梁KFM Micro Slider Type Resistance Sensor 吕梁KSP Circular Tube Miniature Self-reset 吕梁KSC Square Tube Miniature Self-reset Displacement sensor 吕梁KS8X Micro Self-resetting Displacement Sensor 吕梁KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 吕梁KST Self resetting displacement sensor 吕梁KSD Linear Position Sensor 13FLP 吕梁KPFZ Flange-mounted self-resetting resistance ruler 吕梁LEP displacement sensorwith Waterproof and dustproof 吕梁KEP Brushless Sensor with Waterproof and Dustproof 吕梁LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 吕梁KPM9 Mini Type Pull Rod Displacement Sensor 吕梁KSE Rod type displacement sensor 吕梁KSF Micro Slide Type Displacement Sensor 吕梁KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

吕梁MPS-XXXS Pull Wire Displacement Sensor 吕梁MPS-XXS Pull Wire Displacement Sensor 吕梁MPS-XS Pull Wire Displacement Sensor 吕梁MPS-S Pull Wire Displacement Sensor 吕梁MPS-M Pull Wire Displacement Sensor 吕梁MPS-L Pull Wire Displacement Sensor 吕梁MPS-XL Pull Wire Displacement Sensor 吕梁MPSFS2-S Waterproof Absolute Wire Rope Sensor 吕梁MPSFS2-M Waterproof Absolute Wire Rope Sensor 吕梁MPSFS2-L Waterproof Absolute Wire Rope Sensor 吕梁MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 吕梁MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 吕梁MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 吕梁MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 吕梁SM-S Pull Wire Displacement Sensor 吕梁SM-M Pull Wire Displacement Sensor 吕梁WEP-S Pull Wire Displacement Sensor 吕梁WEP-M Pull Wire Displacement Sensor 吕梁WS-S Pull Wire Displacement Sensor 吕梁MDS-S Pull Wire Displacement Sensor 吕梁MPS-XS Magnetic Mounting Rope Displacement Sensor 吕梁MPS-L Magnetic Draw Wire Displacement Sensor 吕梁MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 吕梁MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 吕梁MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Magnetostrictive displacement/liquid level sensor

more+

吕梁Fully Automatic Lubricating Oil Pump

more+

吕梁Electric Automatic Oil Pump / Manual Oil Pump

more+

吕梁MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 吕梁MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 吕梁MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 吕梁MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 吕梁MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 吕梁MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MGH-1205-100T Semi-automatic Butter Lubrication Pump 吕梁MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 吕梁MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 吕梁MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 吕梁MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 吕梁MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 吕梁MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 吕梁MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 吕梁MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 吕梁MRH-1202-100T Semi-automatic Grease Lubrication Pump 吕梁MRH-1232-100TB Automatical Grease Lubrication Pump 吕梁MGH-1202-100T Semi-automatic Butter Lubrication Pump 吕梁MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>吕梁Product>>吕梁Sensors>>吕梁The displacement sensor series for gate water conservancy engineering(can be customized)

吕梁MKDC Pull rod series gate opening external (magnetostrictive) displacement sensor

  • Product classification:The displacement sensor series for gate water conservancy engineering(can be customized)
  • Number of views:2058
  • QR code:
  • Release time:2024-04-08
  • Overview

Product Introduction:

          The change in magnetization direction in ferromagnetic materials can cause a change in the lattice spacing of the medium, resulting in a change in the length and volume of the ferromagnetic material, known as the magnetostriction phenomenon, also known as the Wiedemann effect, and its inverse effect is called the Villarreal effect. The principle of magnetostrictive displacement sensor is to generate a strain pulse signal when two different magnetic fields intersect, and then calculate the time period required for this signal to be detected, in order to convert the accurate position. These two magnetic fields come from one permanent magnet in the magnetic ring and the other excitation pulse generated by electronic components in the sensor electronic compartment. The excitation pulse runs at the speed of sound along the waveguide wire made of magnetostrictive material inside the sensor. When intersecting with the permanent magnetic field in the magnetic ring, the mechanical vibration generated by the waveguide wire forms a strain pulse due to the magnetostriction phenomenon. The strain pulse is quickly detected by the sensing circuit in the electronic chamber. By multiplying the total time from the moment the excitation pulse is generated to the detection of the strain pulse by a fixed sound velocity, we can accurately calculate the position change of the magnet. This process is continuous, so whenever the position of the magnetic ring changes, the new position will be quickly measured. Since the output signal is the true position value, rather than a proportional or amplified signal, there is no signal drift or variation, and there is no need for periodic recalibration like other sensors.

Magnetostrictive sensors are non-contact and never wear out. It has the advantages of high resolution, high precision, high stability, high reliability, fast response time, and long working life. Sensors do not require recalibration or regular maintenance.


Application fields and characteristics :

Suitable for measuring the opening of various gates and displacement of oil cylinders in the water conservancy industry

Suitable for working environments with vibration and motion

● Highly waterproof and sealed, with a protection level of IP68 ● Resistant to harsh environments and strong corrosion resistance

● Absolute value output ● Multiple signal outputs available for selection

● Anti polarity selection, anti static, anti lightning, anti surge, anti corrosion, anti vibration, strong anti-interference ability


Technical parameters and installation dimensions:


ModelMKDC Working stroke50-12000mm 
Resolution
0.05mmNon-linear error≤±0.05%FS
Repeatability accuracy≤±0.005%FSPower supplyDC24V
Output
4-20mA, 0-20mA, CANopen RS485, SSI Lightning protectioncan be offered
Working Current
≤50mAPolarity protection≤-30VDC
Overpressure protection≤36vdcInsulation protectionDC500V(Housing grounding)
working temperature-30℃~+85Storage temperature-45~90
IPIP68
Vibration shock10Hz-2000HZ, 5g
Installation directionVertical, inclined, horizontalInstallation methodHoop installation (customizable size)
IP
IP68Vibration shock10Hz-2000HZ, 5g
Material304 Stainless steel (fresh water); 316 stainless steel (seawater)
Electrical connectorsWaterproof joint straight lead, cable standard length 10m (length can be customized)


037e7d18707bda3d6dbc9655f23e1020_1727229998313797.jpg

image.png



Installation precautions :


1. Before installation, check the physical object according to the assembly drawing, familiarize yourself with the names, installation positions, and installation points of each installation component, and then refer to the drawings and installation instructions for installation. The following installation steps are routine steps. Due to different on-site environments, the installation steps and methods can be flexibly adjusted according to the actual situation;

2. If conditions permit, the gate can be opened and closed to the appropriate position for installation. Generally, fully open the gate is the best installation position. According to the installation drawings, weld the measuring rod connecting bracket to the piston rod lifting ear, and install the guide sleeve onto the oil cylinder. According to the actual situation, the installation position of the clamp does not need to be strictly installed according to the positions indicated in the drawings, but should be evenly distributed, subjected to force, and easy to install. However, the position of the guide sleeve relative to the oil cylinder cannot be changed, otherwise it will cause the sensor to be in a reading blind zone when the gate is fully closed, or the sensor will have too much reading stroke, which cannot reach the design measurement stroke after resetting;

3. Choose the installation steps based on the actual situation on site. During installation, you can first assemble the guide sleeve and clamp (use the guide sleeve clamp to assemble the guide sleeve and clamp), and then lift both onto the oil cylinder together. Alternatively, you can first install the clamp on the oil cylinder, lift the casing onto the oil cylinder, and then assemble it with the clamp. Generally, you choose to assemble it first and then lift it. When installing and lifting clamps, the opening should be oriented towards the side that is convenient for installation and fixation. Before determining the position of the clamp, do not tighten the screw. Wait until the guide sleeve is adjusted to be directly above the oil cylinder and in a straight line before fixing the screw.

4. Installation precautions: (1) The measuring rod should be marked with the "working surface" label, and the side with multiple magnetic segments should be the working surface (metal can be adsorbed). If the measuring rod is removed, it must be restored with the sensing surface facing the Hall sensor; (2) Due to the smoothness of stainless steel pipes, the ropes must be firmly fixed during lifting to prevent them from falling off;

5. After fixing the guide sleeve, move the measuring rod to the gate lifting ear. Connect the joint bearing on the measuring rod to the clamp bracket on the lifting ear. Note that the clamp on the measuring rod must be in a straight line with the guide sleeve;

6. If the gate is in a fully open or fully closed state during installation, when connecting the measuring rod, you can check whether the "full range marking line" (check when fully open installation) or "zero point marking line" (check when fully closed installation) on the measuring rod is at the pipe mouth. The marking line can slightly enter the pipe (generally within 20mm into the pipe, not too much to prevent insufficient travel), but it cannot be exposed. If the marking line is exposed at the pipe mouth, the measuring rod or guide sleeve should be adjusted so that it is not outside the pipe mouth (under the premise of ample space, adjusting the connecting clamp of the measuring rod is simple). This operation is to prevent the measuring rod from being in the blind spot position of Hall sensor detection when fully closed; If the gate is not fully open or fully closed during installation, please install according to the position marked on the drawing, align the guide sleeve with the oil cylinder installation seat, as shown in the installation drawing, and adjust the position of the clamp appropriately according to the situation;

7. Install junction boxes in appropriate locations for easy installation and wiring, and effective protection. The Hall sensor and proximity switch cables are threaded through pipes and connected to a junction box (the terminals inside the junction box are defined), and then connected to the electrical control cabinet;

8. Connect the cables to the corresponding terminals inside the control cabinet according to the installation instructions.



  • Application