固原KTC11 Pull Rod Linear Displacement Sensor 固原KTC1/LWHPull Rod Linear Displacement Sensor 固原KTF Slider Displacement Sensor 固原KTC2/KTC21 Pull Rod Linear Displacement Sensor 固原KTF1 Slider Displacement Sensor 固原KTR11/12,KTR2 Spring Self-return Position Potentiometer 固原KTM Miniature Pull Rod Displacement Sensor 固原KTR3/KTR4 Spring Self-return Position Potentiometer 固原TR Spring Self-return Position Potentiometer 固原KPC1H Hersman Plug out Pull-rod Resistance 固原KPC1 Articulated Electronic Ruler 固原KPM23 Small Articulated Resistance Sensor 固原KPM22 Small Articulated Resistance Sensor 固原KPM18 Small Articulated Resistance Sensor 固原KPM16 Shock Travel Sensor 固原KPM12 Shock Travel Sensor 固原KPM12R1/KPM12R2 Self-reset Resistance Sensor 固原WY-01 Resistive Displacement Sensor 固原WDL Rod Type Displacement Sensor 固原KSE Pull Rod Displacement Sensor 固原KPF Flange Displacement Sensor 固原KFM Micro Slider Type Resistance Sensor 固原KSP Circular Tube Miniature Self-reset 固原KSC Square Tube Miniature Self-reset Displacement sensor 固原KS8X Micro Self-resetting Displacement Sensor 固原KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 固原KST Self resetting displacement sensor 固原KSD Linear Position Sensor 13FLP 固原KPFZ Flange-mounted self-resetting resistance ruler 固原LEP displacement sensorwith Waterproof and dustproof 固原KEP Brushless Sensor with Waterproof and Dustproof 固原LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 固原KPM9 Mini Type Pull Rod Displacement Sensor 固原KSE Rod type displacement sensor 固原KSF Micro Slide Type Displacement Sensor 固原KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

固原MPS-XXXS Pull Wire Displacement Sensor 固原MPS-XXS Pull Wire Displacement Sensor 固原MPS-XS Pull Wire Displacement Sensor 固原MPS-S Pull Wire Displacement Sensor 固原MPS-M Pull Wire Displacement Sensor 固原MPS-L Pull Wire Displacement Sensor 固原MPS-XL Pull Wire Displacement Sensor 固原MPSFS2-S Waterproof Absolute Wire Rope Sensor 固原MPSFS2-M Waterproof Absolute Wire Rope Sensor 固原MPSFS2-L Waterproof Absolute Wire Rope Sensor 固原MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 固原MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 固原MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 固原MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 固原MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 固原MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 固原MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 固原MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 固原MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 固原SM-S Pull Wire Displacement Sensor 固原SM-M Pull Wire Displacement Sensor 固原WEP-S Pull Wire Displacement Sensor 固原WEP-M Pull Wire Displacement Sensor 固原WS-S Pull Wire Displacement Sensor 固原MDS-S Pull Wire Displacement Sensor 固原MPS-XS Magnetic Mounting Rope Displacement Sensor 固原MPS-L Magnetic Draw Wire Displacement Sensor 固原MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 固原MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 固原MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Magnetostrictive displacement/liquid level sensor

more+

固原Fully Automatic Lubricating Oil Pump

more+

固原Electric Automatic Oil Pump / Manual Oil Pump

more+

固原MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 固原MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 固原MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 固原MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 固原MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 固原MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 固原MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 固原MGH-1205-100T Semi-automatic Butter Lubrication Pump 固原MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 固原MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 固原MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 固原MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 固原MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 固原MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 固原MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 固原MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 固原MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 固原MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 固原MRH-1202-100T Semi-automatic Grease Lubrication Pump 固原MRH-1232-100TB Automatical Grease Lubrication Pump 固原MGH-1202-100T Semi-automatic Butter Lubrication Pump 固原MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>固原Product>>固原Sensors>>固原The displacement sensor series for gate water conservancy engineering(can be customized)

固原SMZFS2 Gate Opening (pull rope magnetic encoder) Displacement Sensor MPSZFS2-ZM

  • Product classification:The displacement sensor series for gate water conservancy engineering(can be customized)
  • Number of views:1116
  • QR code:
  • Release time:2024-09-25
  • Overview

I. SMZFS2 Gate opening (wire magnetic encoder) displacement sensor overview:

1. Gate opening (pull magnetic encoder) displacement sensor, also known as pull rope encoder, pull rope ruler, pull wire ruler, pull wire encoder, pull rope displacement sensor, the sensor adopts the multi-loop magnetic induction absolute encoder independently developed by Miran company, the internal use of high-strength potion-sealing adhesive package (limited protection level IP68), Thus, the magnetic induction absolute alignment encoder can work normally under water for a long time.

2. Gate opening (magnetic encoder) displacement sensor in the structure of the exquisite integration, fully combined with the advantages of Angle sensor and linear displacement sensor, to become a long measurement stroke, simple installation, with high precision measurement of the absolute value of the pull wire displacement sensor.

 

II. SMZFS2 Gate opening (pull wire magnetic encoder) Displacement sensor Technical parameters:


Project Specifications

Details

Remark

Effective length

100mm-4000mm

 


 

Power supply

DC12V~DC24V

(Voltage/current/RS485)

Fluctuation below 5%

Power supply voltage VCC consumption current

40mA

no mutation

 


Signal output

Voltage:0-5V,0-10V, 
Current:4-20mA,

Digital:RS485

Pulse signal:A/B/Z

 

Absolute position output type

 

Linear accuracy

±0.25%FS


repeatability

±0.05%FS


Resolution

Analog output 16 bits, digital output 12 bits


Lightning protection/surge protection

Yes (GB/T 17626.5-2019)


Anti-static

Yes (GB/T 17626.2)


Corrosion protection

Salt spray test 24H, level 6


Vibration resistance

10Hz to 2000Hz,5g


Wire diameter specification

1.5mm(SUS316)


Working temperature

-10℃~60℃

At low temperature, no crystallization must be maintained 

IP

IP68


 

III.SMZFS2 Gate opening (pull magnetic encoder) displacement sensor wiring method (specific physical wiring shall prevail) :


Current 

Voltage

RS485

     Red wire         

DC12V~DC24V      

  DC12V~DC24V        

DC12V~DC24V      

Black wire

  0V

  0V

  0V

Green Wire

Output 4-20mA

  Output 0-5V.0-10V

RS485   A+

White wire

None 

None

RS485   B-

Shield Ground

   GND

  GND

 GND

 

IV、SMZFS2 Gate opening (cable magnetic encoder) Displacement sensor Installation size:

 

V. SMZFS2 Gate opening (pull magnetic encoder) displacement sensor selection guide:

image.png

 

VI. Matters need attention:

1. The use of the bottom 6 (any three sides, pulling head surface can not be fixed) to fix the screw hole, according to the site and machine installation space facilities need, direct installation or additional protection or other mechanical use.

2. Stainless steel cable installation, must pay attention to the horizontal Angle, that is, as far as possible to make the cable from the outlet to the moving part of the mechanism, the horizontal slide during work.

3.Keep a small Angle (allowable deviation +/-3°) to ensure measurement accuracy and cable life.
The steel cable body is stainless steel and coated with fluorine layer, do not let it be hurt by external forces, burn, impact and other improper things: excessive dust, debris accumulation or enough to damage the steel cable stored in the internal pulley or wire outlet will cause damage to the steel cable, resulting in failure of operation.

4. Not installed in the workbench or fixed sitting, do not use hands or other products to pull out the steel cable and let it bounce back instantaneously. This will cause the cable to break and damage the body structure.

5. If used in the non-linear movement of the mechanism, please install the appropriate pulley operation.

6.If used in bad environment or special occasions, please install your own protection mechanism

 

VII. Application Fields

Crack measurement and monitoring, bridge measurement and monitoring, storage location, reservoir dam protection, gate opening control, pressure machinery, paper making machinery, textile machinery, sheet metal machinery, packaging machinery, printing machinery, level control instrument, construction machinery, industrial robot, injection machine, woodworking machinery, elevator, air compressor/hydraulic press, height machine, X-Y axis and other length displacement, liquid level and other related dimensional measurement and position control.


  • Application