TEL:

189 8877 5298

Announcement:

Product

more+

保定Sensors

more+

Linear Position Sensor

保定KTC1/LWHPull Rod Linear Displacement Sensor 保定KTC2 Pull Rod Linear Displacement Sensor 保定KTF Slider Displacement Sensor 保定KTF1 Slider Displacement Sensor 保定KPC1 Articulated Electronic Ruler 保定KPC1H Hersman Plug out Pull-rod Resistance 保定KPM12R1/KPM12R2 Self-reset Resistance Sensor 保定KPM16 Shock Travel Sensor 保定KPM18 Small Articulated Resistance Sensor 保定KPM22 Small Articulated Resistance Sensor 保定KPM23 Small Articulated Resistance Sensor 保定KPM12 Shock Travel Sensor 保定WY-01 Resistive Displacement Sensor_COPY 保定WY-01 Resistive Displacement Sensor 保定KSE Pull Rod Displacement Sensor 保定KSC Square Tube Miniature Self-reset Displacement sensor 保定KSP Circular Tube Miniature Self-reset 保定KTR11/12,KTR2 Spring Self-return Position Potentiometer 保定KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 保定KSN Self-resetting Displacement Sensor 保定KFM Micro Slider Type Resistance Sensor 保定WDL Rod Type Displacement Sensor 保定KPF Flange Displacement Sensor 保定KTM Miniature Pull Rod Displacement Sensor 保定KPFZ Flange-mounted self-resetting resistance ruler 保定KSD Linear Position Sensor 13FLP 保定KST Self resetting displacement sensor 保定KS8X Micro Self-resetting Displacement Sensor 保定KSE Rod type displacement sensor 保定KPM9 Mini Type Pull Rod Displacement Sensor 保定LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 保定KEP Brushless Sensor with Waterproof and Dustproof 保定LEP displacement sensorwith Waterproof and dustproof
more+

保定The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

保定WS-S Pull Wire Displacement Sensor 保定MPS-XL Pull Wire Displacement Sensor 保定MPS-L Pull Wire Displacement Sensor 保定MPS-L Magnetic Draw Wire Displacement Sensor 保定MPSFS2-S Waterproof Absolute Wire Rope Sensor 保定LPS-M Pull Wire Displacement Sensor 保定LPS-S Pull Wire Displacement Sensor 保定MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 保定MPS-XS Magnetic Mounting Rope Displacement Sensor 保定MPSFS2-M Waterproof Absolute Wire Rope Sensor 保定MPS-XXXS Pull Wire Displacement Sensor 保定MPS-XXS Pull Wire Displacement Sensor 保定MPS-XS Pull Wire Displacement Sensor 保定MPS-S Pull Wire Displacement Sensor 保定MPS-M Pull Wire Displacement Sensor 保定MDS-S Pull Wire Displacement Sensor 保定SM-S Pull Wire Displacement Sensor 保定WEP-S Pull Wire Displacement Sensor 保定WEP-M Pull Wire Displacement Sensor 保定SM-M Pull Wire Displacement Sensor 保定MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 保定MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 保定MPSFS2-L Waterproof Absolute Wire Rope Sensor 保定MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 保定MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 保定MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 保定MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 保定MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 保定MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 保定MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 保定MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 保定MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

保定Spoke type weighing sensors《Special Customizable》

more+

保定Three pulley tension sensor

more+

保定Gap displacement sensor

more+

保定Wireless data transmission radio/wireless transmission module

more+

保定RS485 to USB converter

more+

保定Wansung position sensor

more+

Digital Indicator

more+

保定CH6 Displacement Display Instrument

more+

保定XSA Digital Display Instrument

more+

保定XSAW Potentiometer Digital Display Instrument

more+

保定XSAEW Digital Display Instrument

more+

保定XSEW Digital Display Instrument

more+

保定XSK Digital Display Instrument

more+

保定XSAE Displacement Sensor Digital Display Instrument

more+

保定Fully Automatic Lubricating Oil Pump

Your current location is:Home>>保定Product>>保定Sensors>>保定Transfer module and digital display instrument

保定XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:581
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application