TEL:

189 8877 5298

Announcement:

Product

more+

株洲Sensors

more+

Linear Position Sensor

株洲KTC1/LWHPull Rod Linear Displacement Sensor 株洲KTC2 Pull Rod Linear Displacement Sensor 株洲KTF Slider Displacement Sensor 株洲KTF1 Slider Displacement Sensor 株洲KPC1 Articulated Electronic Ruler 株洲KPC1H Hersman Plug out Pull-rod Resistance 株洲KPM12R1/KPM12R2 Self-reset Resistance Sensor 株洲KPM16 Shock Travel Sensor 株洲KPM18 Small Articulated Resistance Sensor 株洲KPM22 Small Articulated Resistance Sensor 株洲KPM23 Small Articulated Resistance Sensor 株洲KPM12 Shock Travel Sensor 株洲WY-01 Resistive Displacement Sensor_COPY 株洲WY-01 Resistive Displacement Sensor 株洲KSE Pull Rod Displacement Sensor 株洲KSC Square Tube Miniature Self-reset Displacement sensor 株洲KSP Circular Tube Miniature Self-reset 株洲KTR11/12,KTR2 Spring Self-return Position Potentiometer 株洲KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 株洲KSN Self-resetting Displacement Sensor 株洲KFM Micro Slider Type Resistance Sensor 株洲WDL Rod Type Displacement Sensor 株洲KPF Flange Displacement Sensor 株洲KTM Miniature Pull Rod Displacement Sensor 株洲KPFZ Flange-mounted self-resetting resistance ruler 株洲KSD Linear Position Sensor 13FLP 株洲KST Self resetting displacement sensor 株洲KS8X Micro Self-resetting Displacement Sensor 株洲KSE Rod type displacement sensor 株洲KPM9 Mini Type Pull Rod Displacement Sensor 株洲LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 株洲KEP Brushless Sensor with Waterproof and Dustproof 株洲LEP displacement sensorwith Waterproof and dustproof
more+

株洲The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

株洲WS-S Pull Wire Displacement Sensor 株洲MPS-XL Pull Wire Displacement Sensor 株洲MPS-L Pull Wire Displacement Sensor 株洲MPS-L Magnetic Draw Wire Displacement Sensor 株洲MPSFS2-S Waterproof Absolute Wire Rope Sensor 株洲LPS-M Pull Wire Displacement Sensor 株洲LPS-S Pull Wire Displacement Sensor 株洲MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 株洲MPS-XS Magnetic Mounting Rope Displacement Sensor 株洲MPSFS2-M Waterproof Absolute Wire Rope Sensor 株洲MPS-XXXS Pull Wire Displacement Sensor 株洲MPS-XXS Pull Wire Displacement Sensor 株洲MPS-XS Pull Wire Displacement Sensor 株洲MPS-S Pull Wire Displacement Sensor 株洲MPS-M Pull Wire Displacement Sensor 株洲MDS-S Pull Wire Displacement Sensor 株洲SM-S Pull Wire Displacement Sensor 株洲WEP-S Pull Wire Displacement Sensor 株洲WEP-M Pull Wire Displacement Sensor 株洲SM-M Pull Wire Displacement Sensor 株洲MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 株洲MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 株洲MPSFS2-L Waterproof Absolute Wire Rope Sensor 株洲MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 株洲MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 株洲MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 株洲MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 株洲MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 株洲MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 株洲MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 株洲MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 株洲MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

株洲Spoke type weighing sensors《Special Customizable》

more+

株洲Three pulley tension sensor

more+

株洲Gap displacement sensor

more+

株洲Wireless data transmission radio/wireless transmission module

more+

株洲RS485 to USB converter

more+

株洲Wansung position sensor

more+

Digital Indicator

more+

株洲CH6 Displacement Display Instrument

more+

株洲XSA Digital Display Instrument

more+

株洲XSAW Potentiometer Digital Display Instrument

more+

株洲XSAEW Digital Display Instrument

more+

株洲XSEW Digital Display Instrument

more+

株洲XSK Digital Display Instrument

more+

株洲XSAE Displacement Sensor Digital Display Instrument

more+

株洲Fully Automatic Lubricating Oil Pump

Your current location is:Home>>株洲Product>>株洲Sensors>>株洲Transfer module and digital display instrument

株洲XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:576
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)