TEL:

189 8877 5298

Announcement:

Product

more+

驻马店Sensors

more+

Linear Position Sensor

驻马店KTC1/LWHPull Rod Linear Displacement Sensor 驻马店KTC2 Pull Rod Linear Displacement Sensor 驻马店KTF Slider Displacement Sensor 驻马店KTF1 Slider Displacement Sensor 驻马店KPC1 Articulated Electronic Ruler 驻马店KPC1H Hersman Plug out Pull-rod Resistance 驻马店KPM12R1/KPM12R2 Self-reset Resistance Sensor 驻马店KPM16 Shock Travel Sensor 驻马店KPM18 Small Articulated Resistance Sensor 驻马店KPM22 Small Articulated Resistance Sensor 驻马店KPM23 Small Articulated Resistance Sensor 驻马店KPM12 Shock Travel Sensor 驻马店WY-01 Resistive Displacement Sensor_COPY 驻马店WY-01 Resistive Displacement Sensor 驻马店KSE Pull Rod Displacement Sensor 驻马店KSC Square Tube Miniature Self-reset Displacement sensor 驻马店KSP Circular Tube Miniature Self-reset 驻马店KTR11/12,KTR2 Spring Self-return Position Potentiometer 驻马店KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 驻马店KSN Self-resetting Displacement Sensor 驻马店KFM Micro Slider Type Resistance Sensor 驻马店WDL Rod Type Displacement Sensor 驻马店KPF Flange Displacement Sensor 驻马店KTM Miniature Pull Rod Displacement Sensor 驻马店KPFZ Flange-mounted self-resetting resistance ruler 驻马店KSD Linear Position Sensor 13FLP 驻马店KST Self resetting displacement sensor 驻马店KS8X Micro Self-resetting Displacement Sensor 驻马店KSE Rod type displacement sensor 驻马店KPM9 Mini Type Pull Rod Displacement Sensor 驻马店LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 驻马店KEP Brushless Sensor with Waterproof and Dustproof 驻马店LEP displacement sensorwith Waterproof and dustproof
more+

Rope/wire displacement sensor

驻马店WS-S Pull Wire Displacement Sensor 驻马店MPS-XL Pull Wire Displacement Sensor 驻马店MPS-L Pull Wire Displacement Sensor 驻马店MPS-L Magnetic Draw Wire Displacement Sensor 驻马店MPSFS2-S Waterproof Absolute Wire Rope Sensor 驻马店LPS-M Pull Wire Displacement Sensor 驻马店LPS-S Pull Wire Displacement Sensor 驻马店MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 驻马店MPS-XS Magnetic Mounting Rope Displacement Sensor 驻马店MPSFS2-M Waterproof Absolute Wire Rope Sensor 驻马店MPS-XXXS Pull Wire Displacement Sensor 驻马店MPS-XXS Pull Wire Displacement Sensor 驻马店MPS-XS Pull Wire Displacement Sensor 驻马店MPS-S Pull Wire Displacement Sensor 驻马店MPS-M Pull Wire Displacement Sensor 驻马店MDS-S Pull Wire Displacement Sensor 驻马店SM-S Pull Wire Displacement Sensor 驻马店WEP-S Pull Wire Displacement Sensor 驻马店WEP-M Pull Wire Displacement Sensor 驻马店SM-M Pull Wire Displacement Sensor 驻马店MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 驻马店MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 驻马店MPSFS2-L Waterproof Absolute Wire Rope Sensor 驻马店MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 驻马店MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 驻马店MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 驻马店MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 驻马店MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 驻马店MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 驻马店MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 驻马店MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 驻马店MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

驻马店Spoke type weighing sensors《Special Customizable》

more+

驻马店Three pulley tension sensor

more+

驻马店Gap displacement sensor

more+

驻马店Wireless data transmission radio/wireless transmission module

more+

驻马店RS485 to USB converter

more+

驻马店Wansung position sensor

more+

Digital Indicator

more+

驻马店CH6 Displacement Display Instrument

more+

驻马店XSA Digital Display Instrument

more+

驻马店XSAW Potentiometer Digital Display Instrument

more+

驻马店XSAEW Digital Display Instrument

more+

驻马店XSEW Digital Display Instrument

more+

驻马店XSK Digital Display Instrument

more+

驻马店XSAE Displacement Sensor Digital Display Instrument

more+

驻马店Fully Automatic Lubricating Oil Pump

Your current location is:Home>>驻马店Product>>驻马店Sensors>>驻马店Transfer module and digital display instrument

驻马店XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:446
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application