TEL:

180 3818 6775

Announcement:

Product

新泰Sensors

more+

Linear Position Sensor

more+

新泰KTC11 Pull Rod Linear Displacement Sensor 新泰KTC1/LWHPull Rod Linear Displacement Sensor 新泰KTF Slider Displacement Sensor 新泰KTC2/KTC21 Pull Rod Linear Displacement Sensor 新泰KTF1 Slider Displacement Sensor 新泰KTR11/12,KTR2 Spring Self-return Position Potentiometer 新泰KTF2 Slider Displacement Sensor 新泰KTM Miniature Pull Rod Displacement Sensor 新泰KTR3/KTR4 Spring Self-return Position Potentiometer 新泰TR Spring Self-return Position Potentiometer 新泰KPC1H Hersman Plug out Pull-rod Resistance 新泰KPC1 Articulated Electronic Ruler 新泰KPM23 Small Articulated Resistance Sensor 新泰KPM22 Small Articulated Resistance Sensor 新泰KPM18 Small Articulated Resistance Sensor 新泰KPM16 Shock Travel Sensor 新泰KPM12 Shock Travel Sensor 新泰KPM12R1/KPM12R2 Self-reset Resistance Sensor 新泰WY Series High sealing Class of Resistive Displacement Sensor 新泰WDL Rod Type Displacement Sensor 新泰KSE Pull Rod Displacement Sensor 新泰KPF Flange Displacement Sensor 新泰KFM Micro Slider Type Resistance Sensor 新泰KSP Circular Tube Miniature Self-reset 新泰KSC Square Tube Miniature Self-reset Displacement sensor 新泰KS8X Micro Self-resetting Displacement Sensor 新泰KS8 S8FLP10A 8FLP10D,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 新泰KST Self resetting displacement sensor 新泰KSD Linear Position Sensor 13FLP 新泰KPFZ Flange-mounted self-resetting resistance ruler 新泰LEP displacement sensorwith Waterproof and dustproof 新泰KEP Brushless Sensor with Waterproof and Dustproof 新泰LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 新泰KPM9 Mini Type Pull Rod Displacement Sensor 新泰KSE Rod type displacement sensor 新泰KSF Micro Slide Type Displacement Sensor 新泰KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

新泰MPS-XXXS Pull Wire Displacement Sensor 新泰MPS-XXS Pull Wire Displacement Sensor 新泰MPS-XS Pull Wire Displacement Sensor 新泰MPS-S Pull Wire Displacement Sensor 新泰MPS-M Pull Wire Displacement Sensor 新泰MPS-L Pull Wire Displacement Sensor 新泰MPS-XL Pull Wire Displacement Sensor 新泰MPSFS2-S Waterproof Absolute Wire Rope Sensor 新泰MPSFS2-M Waterproof Absolute Wire Rope Sensor 新泰MPSFS2-L Waterproof Absolute Wire Rope Sensor 新泰MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 新泰MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 新泰MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 新泰MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新泰MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新泰MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新泰MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新泰MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新泰MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 新泰SM-S Pull Wire Displacement Sensor 新泰SM-M Pull Wire Displacement Sensor 新泰WEP-S Pull Wire Displacement Sensor 新泰WEP-M Pull Wire Displacement Sensor 新泰WS-S Pull Wire Displacement Sensor 新泰MDS-S Pull Wire Displacement Sensor 新泰MPS-XS Magnetic Mounting Rope Displacement Sensor 新泰MPS-L Magnetic Draw Wire Displacement Sensor 新泰MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 新泰MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 新泰MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Magnetostrictive displacement/liquid level sensor

more+

新泰MTM2 Slider Magnetostrictive Sensor 新泰MTM3 Suspension Slider Magnetostrictive Sensor 新泰GUC2500 Mine-Grade Intrinsically Safe Magnetostrictive Displacement Sensor 新泰GUC2800 Mine-Grade Intrinsically Safe Magnetostrictive Displacement Sensor 新泰MTW Magnetic Suspension Series Magnetostrictive Displacement Sensor 新泰MPM1 Pull-rod Magnetostrictive Displacement Sensor 新泰MPM1 Two-End Fisheye Articulated Magnetostrictive Displacement Sensor 新泰MR1 Flexible Soft Cable Type Magnetostrictive Displacement Sensor 新泰MTL2 Magnetostrictive Displacement/level Sensor 新泰MTL4 High Resolution Magnetostrictive Displacement Sensor with Magnetic Ring 新泰MTL4C Magnetostrictive Displacement Sensor with Ether CAT signal output 新泰MTL4F Magnetostrictive Liquid Level Sensor 新泰MTC Pull Rod Magnetostrictive Displacement Sensor 新泰MTF Slider Magnetostrictive Displacement Sensor 新泰MTF1/MTF2 slider type magnetostrictive 新泰MTF1/MTF2 Slider type Magnetostrictive Displacement Sensor with Ether CAT signal output 新泰MTS Magnetostrictive Displacement/level Sensor 新泰MTG Pull Rod Magnetostrictive Displacement Sensor 新泰MTL5 Reinforced Sealed Magnetostrictive 新泰MTL7 Magnetostrictive Liquid Level Sensor 新泰MFTS Split-type Magnetostrictive Displacement Sensor 新泰MTM5 Vulcanization Machine Special Magnetic Suspension Displacement Sensor 新泰MTM5 Magnetic Suspension Displacement Sensor with Ether CAT signal output 新泰MPM Articulated Magnetostrictive Displacement Sensor 新泰MF Anti-corrosion Magnetostrictive Displacement Sensor 新泰MR Flexible Cable Magnetostrictive Level Sensor 新泰MTM Low Power Guide Slide type Magnetostrictive Displacement Sensor 新泰MTL3 Low-power (two-wire) Magnetostrictive Displacement Sensor 新泰MFTS1 Split-type Magnetostrictive Displacement Sensor
新泰Fully Automatic Lubricating Oil Pump

more+

新泰Electric Automatic Oil Pump / Manual Oil Pump

more+

新泰MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 新泰MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 新泰MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 新泰MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 新泰MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 新泰MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 新泰MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 新泰MGH-1205-100T Semi-automatic Butter Lubrication Pump 新泰MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 新泰MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 新泰MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 新泰MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 新泰MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 新泰MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 新泰MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 新泰MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 新泰MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 新泰MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 新泰MRH-1202-100T Semi-automatic Grease Lubrication Pump 新泰MRH-1232-100TB Automatical Grease Lubrication Pump 新泰MGH-1202-100T Semi-automatic Butter Lubrication Pump 新泰MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>新泰Product>>新泰Sensors>>Magnetostrictive displacement/liquid level sensor

新泰MPM1 Pull-rod Magnetostrictive Displacement Sensor

  • Product classification:Magnetostrictive displacement/liquid level sensor
  • Number of views:125
  • QR code:
  • Release time:2026-09-29
  • Overview

Overview of MPM1 Pull-Rod Magnetostrictive Displacement Sensor:

In ferromagnetic materials, a change in the direction of magnetization will cause a change in the lattice spacing of the medium, thereby altering the length and volume of the ferromagnetic material, which is known as the magnetostrictive phenomenon, also called the Widman effect, and its reverse effect is called the Villari effect.

The principle of magnetostrictive displacement sensors is to generate a strain pulse signal when two different magnetic fields intersect, and then calculate the time period required for this signal to be detected, thereby converting it into an accurate position. These two magnetic fields, one from the permanent magnet in the magnetic ring and the other from the excitation pulses generated by the electronic components in the sensor's electronic housing. The excitation pulse travels at the speed of sound along the waveguide wire made of magnetostrictive material inside the sensor. When intersecting with the permanent magnetic field in the magnetic ring, due to the magnetostrictive phenomenon, the mechanical vibration generated by the waveguide wire forms a strain pulse. The strain pulse was quickly detected by the sensing circuit in the electronic compartment. From the moment the excitation pulse is generated to the total time when the strain pulse is detected, multiplied by a fixed speed of sound, we can accurately calculate the position change of the magnet. This process is continuous, so whenever the position of the magnetic ring changes, the new position will be measured quickly. Since the output signal is a true position value rather than a proportional or signal that requires further amplification processing, there is no signal drift or value change, and it is not necessary to recalibrate regularly like other sensors.

The magnetostrictive sensor is non-contact and never wears out. It features high resolution, high precision, high stability, high reliability, fast response time and long working life. The sensor does not need to be recalibrated or maintained regularly.

 

Technical parameters of MPM1 pull-rod magnetostrictive displacement sensor:

Model

MPM Series Magnetostrictive Displacement Sensor with Pull Rod

Resolution

≤0.01mm~0.001mm

Effective Stroke

80mm-1000mm

Non-linearity Error

≤±0.05%FS

Repeatability

≤±0.005%FS

Supply Voltage

DC24V

Hysteresis

≤0.001%FS

Temperature Stability

≤0.002%/℃

Output Signal

4-20mA, 0-20mA, 0-5V, 0-10V, RS485(MODBUS-RTU), CANopen, SSI, Start-stop

Rod Material

Default: 0Cr18Ni9 (304 Stainless Steel); Customizable: 316 Stainless Steel

Load Capacity

Voltage output load ≥4KΩ, Current output load ≤500Ω

Cable Connection

Waterproof cable gland

Operating Current

<60mA (varies with stroke length)

Operating Temperature

-40℃~85℃

Protection Rating

IP65, IP67

Reverse Polarity Protection

Max. -30VDC

Overvoltage Protection

Max. 36VDC

Insulation Resistance

>10MΩ

Insulation Strength

500V

Wiring method of MPM1 pull-rod type magnetostrictive displacement sensor:

Before wiring, please check whether the power supply meets the requirement of +24VDC, and the output power of the power supply must be greater than the total power consumption of the product, calculated based on ≤60mA for each sensor with different ranges. If the power supply does not meet the requirements, please replace the power supply to ensure that the sensor can work normally.

 

The wiring method for the analog signal output of the MPM1 pull-rod magnetostrictive displacement sensor:

1. Waterproof connector direct output wiring method:

The sensor has five contacts: positive power supply (brown), negative power supply (black), positive signal output (blue), negative signal output (white), and ground of the housing (shielded wire).

2. Wiring method of aviation plugs:

The sensor has five contacts: ① positive power supply (brown), ② negative power supply (black), ③ positive signal output (blue), ④ negative signal output (white), ⑤ ground of the housing (shielded wire)

Wiring method of MPM1 pull-rod type magnetostrictive displacement sensor

Before wiring, please check whether the power supply meets the requirement of +24VDC, and the output power of the power supply must be greater than the total power consumption of the product, calculated based on ≤60mA for each sensor with different ranges. If the power supply does not meet the requirements, please replace the power supply to ensure that the sensor can work normally.

 

The wiring method for the analog signal output of the MPM1 pull-rod magnetostrictive displacement sensor:

1. Waterproof connector direct output wiring method:

The sensor has five contacts: positive power supply (brown), negative power supply (black), positive signal output (blue), negative signal output (white), and ground of the housing (shielded wire).

2. Wiring method of aviation plugs:

The sensor has five contacts: ① positive power supply (brown), ② negative power supply (black), ③ positive signal output (blue), ④ negative signal output (white), ⑤ ground of the housing (shielded wire)

3. Waterproof connector direct output wiring method (SSI signal output) :

The sensor has seven contacts: ① positive power supply (brown), ② negative power supply (black), ③ positive clock (blue), ④ negative clock (white), ⑤ positive data (green), ⑥ negative data (yellow), ⑦ ground of the housing (shielded wire)

4. Aviation plug wiring method (SSI signal output) :

The sensor has seven contacts: ① positive power supply (brown), ② negative power supply (black), ③ positive clock (blue), ④ negative clock (white), ⑤ positive data (green), ⑥ negative data (yellow), ⑦ ground of the housing (shielded wire)

 

5. Wiring method of CAN open waterproof connector:

The sensor has five common contacts: positive power supply (brown), negative power supply (black), CAN-H(blue), CAN-L (white), and ground (shielded wire).

6. Wiring method of CAN open aviation connector:

The sensor has five common contacts: ① positive power supply (brown), ② negative power supply (black), ③CAN-H(blue), ④CAN-L (white), ⑤ ground (shielded wire)

 

Application fields of MPM1 pull-rod magnetostrictive displacement sensor:

Servo hydraulic cylinder piston position preset and feedback, servo cylinder piston position preset and feedback, grinding machinery position preset and feedback, casting and forging machine tool position preset and feedback, other machinery such as gantry machine tool position preset and feedback, tunnel boring machine, shield machine, coal mining machinery cylinder position preset and feedback, engineering hoisting machinery cylinder position preset and feedback Presetting and feedback of cylinder positions for steel rolling mills and other steel plant machinery, presetting and feedback of cylinder positions for bottle blowing machinery, presetting and feedback of cylinder positions for injection molding machinery, regulation of railways and Bridges, detection of water levels and control of water gates, presetting and feedback of position for wood machinery, presetting and feedback of cylinder liquid levels, presetting and feedback of liquid levels for chemical containers, drinking water and sewage treatment systems Geodetic system, position presetting and feedback of gate opening, measurement of cylinder liquid level.

 

Installation dimensions of the MPM1 pull-rod type magnetostrictive displacement sensor:

20260929011832322.png