TEL:

189 8877 5298

Announcement:

Product

more+

乌兰察布Sensors

more+

Linear Position Sensor

乌兰察布KTC1/LWHPull Rod Linear Displacement Sensor 乌兰察布KTC2 Pull Rod Linear Displacement Sensor 乌兰察布KTF Slider Displacement Sensor 乌兰察布KTF1 Slider Displacement Sensor 乌兰察布KPC1 Articulated Electronic Ruler 乌兰察布KPC1H Hersman Plug out Pull-rod Resistance 乌兰察布KPM12R1/KPM12R2 Self-reset Resistance Sensor 乌兰察布KPM16 Shock Travel Sensor 乌兰察布KPM18 Small Articulated Resistance Sensor 乌兰察布KPM22 Small Articulated Resistance Sensor 乌兰察布KPM23 Small Articulated Resistance Sensor 乌兰察布KPM12 Shock Travel Sensor 乌兰察布WY-01 Resistive Displacement Sensor_COPY 乌兰察布WY-01 Resistive Displacement Sensor 乌兰察布KSE Pull Rod Displacement Sensor 乌兰察布KSC Square Tube Miniature Self-reset Displacement sensor 乌兰察布KSP Circular Tube Miniature Self-reset 乌兰察布KTR11/12,KTR2 Spring Self-return Position Potentiometer 乌兰察布KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 乌兰察布KSN Self-resetting Displacement Sensor 乌兰察布KFM Micro Slider Type Resistance Sensor 乌兰察布WDL Rod Type Displacement Sensor 乌兰察布KPF Flange Displacement Sensor 乌兰察布KTM Miniature Pull Rod Displacement Sensor 乌兰察布KPFZ Flange-mounted self-resetting resistance ruler 乌兰察布KSD Linear Position Sensor 13FLP 乌兰察布KST Self resetting displacement sensor 乌兰察布KS8X Micro Self-resetting Displacement Sensor 乌兰察布KSE Rod type displacement sensor 乌兰察布KPM9 Mini Type Pull Rod Displacement Sensor 乌兰察布LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 乌兰察布KEP Brushless Sensor with Waterproof and Dustproof 乌兰察布LEP displacement sensorwith Waterproof and dustproof
more+

Rope/wire displacement sensor

乌兰察布WS-S Pull Wire Displacement Sensor 乌兰察布MPS-XL Pull Wire Displacement Sensor 乌兰察布MPS-L Pull Wire Displacement Sensor 乌兰察布MPS-L Magnetic Draw Wire Displacement Sensor 乌兰察布MPSFS2-S Waterproof Absolute Wire Rope Sensor 乌兰察布LPS-M Pull Wire Displacement Sensor 乌兰察布LPS-S Pull Wire Displacement Sensor 乌兰察布MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 乌兰察布MPS-XS Magnetic Mounting Rope Displacement Sensor 乌兰察布MPSFS2-M Waterproof Absolute Wire Rope Sensor 乌兰察布MPS-XXXS Pull Wire Displacement Sensor 乌兰察布MPS-XXS Pull Wire Displacement Sensor 乌兰察布MPS-XS Pull Wire Displacement Sensor 乌兰察布MPS-S Pull Wire Displacement Sensor 乌兰察布MPS-M Pull Wire Displacement Sensor 乌兰察布MDS-S Pull Wire Displacement Sensor 乌兰察布SM-S Pull Wire Displacement Sensor 乌兰察布WEP-S Pull Wire Displacement Sensor 乌兰察布WEP-M Pull Wire Displacement Sensor 乌兰察布SM-M Pull Wire Displacement Sensor 乌兰察布MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 乌兰察布MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 乌兰察布MPSFS2-L Waterproof Absolute Wire Rope Sensor 乌兰察布MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 乌兰察布MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 乌兰察布MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 乌兰察布MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 乌兰察布MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 乌兰察布MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 乌兰察布MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 乌兰察布MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 乌兰察布MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

乌兰察布Spoke type weighing sensors《Special Customizable》

more+

乌兰察布Three pulley tension sensor

more+

乌兰察布Gap displacement sensor

more+

乌兰察布Wireless data transmission radio/wireless transmission module

more+

乌兰察布RS485 to USB converter

more+

乌兰察布Wansung position sensor

more+

Digital Indicator

more+

乌兰察布CH6 Displacement Display Instrument

more+

乌兰察布XSA Digital Display Instrument

more+

乌兰察布XSAW Potentiometer Digital Display Instrument

more+

乌兰察布XSAEW Digital Display Instrument

more+

乌兰察布XSEW Digital Display Instrument

more+

乌兰察布XSK Digital Display Instrument

more+

乌兰察布XSAE Displacement Sensor Digital Display Instrument

more+

乌兰察布Fully Automatic Lubricating Oil Pump

Your current location is:Home>>乌兰察布Product>>乌兰察布Sensors>>乌兰察布Transfer module and digital display instrument

乌兰察布XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:491
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application