TEL:

180 3818 6775

Announcement:

Product

渭南Sensors

more+

Linear Position Sensor

more+

渭南KTC11 Pull Rod Linear Displacement Sensor 渭南KTC1/LWHPull Rod Linear Displacement Sensor 渭南KTF Slider Displacement Sensor 渭南KTC2/KTC21 Pull Rod Linear Displacement Sensor 渭南KTF1 Slider Displacement Sensor 渭南KTR11/12,KTR2 Spring Self-return Position Potentiometer 渭南KTM Miniature Pull Rod Displacement Sensor 渭南KTR3/KTR4 Spring Self-return Position Potentiometer 渭南TR Spring Self-return Position Potentiometer 渭南KPC1H Hersman Plug out Pull-rod Resistance 渭南KPC1 Articulated Electronic Ruler 渭南KPM23 Small Articulated Resistance Sensor 渭南KPM22 Small Articulated Resistance Sensor 渭南KPM18 Small Articulated Resistance Sensor 渭南KPM16 Shock Travel Sensor 渭南KPM12 Shock Travel Sensor 渭南KPM12R1/KPM12R2 Self-reset Resistance Sensor 渭南WY-01 Resistive Displacement Sensor 渭南WDL Rod Type Displacement Sensor 渭南KSE Pull Rod Displacement Sensor 渭南KPF Flange Displacement Sensor 渭南KFM Micro Slider Type Resistance Sensor 渭南KSP Circular Tube Miniature Self-reset 渭南KSC Square Tube Miniature Self-reset Displacement sensor 渭南KS8X Micro Self-resetting Displacement Sensor 渭南KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 渭南KST Self resetting displacement sensor 渭南KSD Linear Position Sensor 13FLP 渭南KPFZ Flange-mounted self-resetting resistance ruler 渭南LEP displacement sensorwith Waterproof and dustproof 渭南KEP Brushless Sensor with Waterproof and Dustproof 渭南LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 渭南KPM9 Mini Type Pull Rod Displacement Sensor 渭南KSE Rod type displacement sensor 渭南KSF Micro Slide Type Displacement Sensor 渭南KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

渭南MPS-XXXS Pull Wire Displacement Sensor 渭南MPS-XXS Pull Wire Displacement Sensor 渭南MPS-XS Pull Wire Displacement Sensor 渭南MPS-S Pull Wire Displacement Sensor 渭南MPS-M Pull Wire Displacement Sensor 渭南MPS-L Pull Wire Displacement Sensor 渭南MPS-XL Pull Wire Displacement Sensor 渭南MPSFS2-S Waterproof Absolute Wire Rope Sensor 渭南MPSFS2-M Waterproof Absolute Wire Rope Sensor 渭南MPSFS2-L Waterproof Absolute Wire Rope Sensor 渭南MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 渭南MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 渭南MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 渭南MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 渭南MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 渭南MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 渭南MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 渭南MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 渭南MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 渭南SM-S Pull Wire Displacement Sensor 渭南SM-M Pull Wire Displacement Sensor 渭南WEP-S Pull Wire Displacement Sensor 渭南WEP-M Pull Wire Displacement Sensor 渭南WS-S Pull Wire Displacement Sensor 渭南MDS-S Pull Wire Displacement Sensor 渭南MPS-XS Magnetic Mounting Rope Displacement Sensor 渭南MPS-L Magnetic Draw Wire Displacement Sensor 渭南MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 渭南MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 渭南MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Magnetostrictive displacement/liquid level sensor

more+

渭南Fully Automatic Lubricating Oil Pump

more+

渭南Electric Automatic Oil Pump / Manual Oil Pump

more+

渭南MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 渭南MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 渭南MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 渭南MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 渭南MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 渭南MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 渭南MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 渭南MGH-1205-100T Semi-automatic Butter Lubrication Pump 渭南MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 渭南MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 渭南MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 渭南MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 渭南MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 渭南MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 渭南MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 渭南MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 渭南MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 渭南MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 渭南MRH-1202-100T Semi-automatic Grease Lubrication Pump 渭南MRH-1232-100TB Automatical Grease Lubrication Pump 渭南MGH-1202-100T Semi-automatic Butter Lubrication Pump 渭南MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>渭南Product>>Digital Indicator>>渭南XSEW Digital Display Instrument

渭南XSEW Digital Instrument

  • Product classification:XSEW Digital Display Instrument
  • Number of views:2153
  • QR code:
  • Release time:2023-11-14
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)



  • Application
Prev:no morer