TEL:

189 8877 5298

Announcement:

Product

more+

同仁Sensors

more+

Linear Position Sensor

同仁KTC1/LWHPull Rod Linear Displacement Sensor 同仁KTC2 Pull Rod Linear Displacement Sensor 同仁KTF Slider Displacement Sensor 同仁KTF1 Slider Displacement Sensor 同仁KPC1 Articulated Electronic Ruler 同仁KPC1H Hersman Plug out Pull-rod Resistance 同仁KPM12R1/KPM12R2 Self-reset Resistance Sensor 同仁KPM16 Shock Travel Sensor 同仁KPM18 Small Articulated Resistance Sensor 同仁KPM22 Small Articulated Resistance Sensor 同仁KPM23 Small Articulated Resistance Sensor 同仁KPM12 Shock Travel Sensor 同仁WY-01 Resistive Displacement Sensor_COPY 同仁WY-01 Resistive Displacement Sensor 同仁KSE Pull Rod Displacement Sensor 同仁KSC Square Tube Miniature Self-reset Displacement sensor 同仁KSP Circular Tube Miniature Self-reset 同仁KTR11/12,KTR2 Spring Self-return Position Potentiometer 同仁KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 同仁KSN Self-resetting Displacement Sensor 同仁KFM Micro Slider Type Resistance Sensor 同仁WDL Rod Type Displacement Sensor 同仁KPF Flange Displacement Sensor 同仁KTM Miniature Pull Rod Displacement Sensor 同仁KPFZ Flange-mounted self-resetting resistance ruler 同仁KSD Linear Position Sensor 13FLP 同仁KST Self resetting displacement sensor 同仁KS8X Micro Self-resetting Displacement Sensor 同仁KSE Rod type displacement sensor 同仁KPM9 Mini Type Pull Rod Displacement Sensor 同仁LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 同仁KEP Brushless Sensor with Waterproof and Dustproof 同仁LEP displacement sensorwith Waterproof and dustproof
more+

同仁The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

同仁WS-S Pull Wire Displacement Sensor 同仁MPS-XL Pull Wire Displacement Sensor 同仁MPS-L Pull Wire Displacement Sensor 同仁MPS-L Magnetic Draw Wire Displacement Sensor 同仁MPSFS2-S Waterproof Absolute Wire Rope Sensor 同仁LPS-M Pull Wire Displacement Sensor 同仁LPS-S Pull Wire Displacement Sensor 同仁MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 同仁MPS-XS Magnetic Mounting Rope Displacement Sensor 同仁MPSFS2-M Waterproof Absolute Wire Rope Sensor 同仁MPS-XXXS Pull Wire Displacement Sensor 同仁MPS-XXS Pull Wire Displacement Sensor 同仁MPS-XS Pull Wire Displacement Sensor 同仁MPS-S Pull Wire Displacement Sensor 同仁MPS-M Pull Wire Displacement Sensor 同仁MDS-S Pull Wire Displacement Sensor 同仁SM-S Pull Wire Displacement Sensor 同仁WEP-S Pull Wire Displacement Sensor 同仁WEP-M Pull Wire Displacement Sensor 同仁SM-M Pull Wire Displacement Sensor 同仁MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 同仁MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 同仁MPSFS2-L Waterproof Absolute Wire Rope Sensor 同仁MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 同仁MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 同仁MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 同仁MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 同仁MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 同仁MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 同仁MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 同仁MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 同仁MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

同仁Spoke type weighing sensors《Special Customizable》

more+

同仁Three pulley tension sensor

more+

同仁Gap displacement sensor

more+

同仁Wireless data transmission radio/wireless transmission module

more+

同仁RS485 to USB converter

more+

同仁Wansung position sensor

more+

Digital Indicator

more+

同仁CH6 Displacement Display Instrument

more+

同仁XSA Digital Display Instrument

more+

同仁XSAW Potentiometer Digital Display Instrument

more+

同仁XSAEW Digital Display Instrument

more+

同仁XSEW Digital Display Instrument

more+

同仁XSK Digital Display Instrument

more+

同仁XSAE Displacement Sensor Digital Display Instrument

more+

同仁Fully Automatic Lubricating Oil Pump

Your current location is:Home>>同仁Product>>同仁Fully Automatic Lubricating Oil Pump>>同仁Electric Automatic Oil Pump / Manual Oil Pump

同仁MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump

  • Product classification:Electric Automatic Oil Pump / Manual Oil Pump
  • Number of views:588
  • QR code:
  • Release time:2023-11-14
  • Overview

MR-2232-3 (3L)      

Self-control Oil Lubrication Pump

米朗MR-2232-3 (3L) 稀油电动润滑油泵微电脑型3L


米朗MR-2232-3 (3L) 稀油电动润滑油泵微电脑型3L



Technical Parameters



Model


Voltage


Rated

ritary

Speed


Power


Current(A)


Rated pressure

kgf/cm²


Max pressure

kgf/cm²


Volume


Discharge

capacity ml/min


Rated

pressure

kgf/cm²


Remarks

MR-2232-300TAB

220V

50/60HZ

2400

18W

0.12

18

35

3L

150-200

CC/min

30-1000

MR-2231 refers to voltage 110V

MR-2232 refers to voltage 220V

MR-2232-300XAB

220V

50/60HZ

MR-2232-310XAB

220V

50/60HZ


*Mode name with " T" is resistant, mode name with “X” is volumetric,mode name with “A” is shade-pole motor


The wiring diagram


米朗MR-2232-3 (3L) 稀油电动润滑油泵微电脑型3L



Performance Characteristics

1.Fuel supply time is set by the UP button(extending the time) and DOWN button(shortening the time) on the right side of the control panel, which can reach up to 200 seconds, with the precision of 1 second. Intermittent time is set by the UP button(extending the time) and DOWN button(shortening the time) on the left side of the control panel, which can

reach up to 999 minutes, with the precision of 0.1 minute. When setting the time, the beat number is 1 if you press the button once. The beat number can be accelerated if you hold down the button. All the settings will take effect immediately after the setting is completed or after the Man button is pressed.

2.When the oil pump shows the EPR alarm, it indicates that the pressure is insufficient. If the the pressure is normal, press the Man button to eliminate the alarm.

3.When the oil pump shows the ERO alarm, the oil quantity is insufficient,and the alarm will be automatically eliminated after refueling .

4.Holding down the Man button is manual test.

(specific lubrication plan can be customized)



  • Application