TEL:

189 8877 5298

Announcement:

Product

more+

铜川Sensors

more+

Linear Position Sensor

铜川KTC1/LWHPull Rod Linear Displacement Sensor 铜川KTC2 Pull Rod Linear Displacement Sensor 铜川KTF Slider Displacement Sensor 铜川KTF1 Slider Displacement Sensor 铜川KPC1 Articulated Electronic Ruler 铜川KPC1H Hersman Plug out Pull-rod Resistance 铜川KPM12R1/KPM12R2 Self-reset Resistance Sensor 铜川KPM16 Shock Travel Sensor 铜川KPM18 Small Articulated Resistance Sensor 铜川KPM22 Small Articulated Resistance Sensor 铜川KPM23 Small Articulated Resistance Sensor 铜川KPM12 Shock Travel Sensor 铜川WY-01 Resistive Displacement Sensor_COPY 铜川WY-01 Resistive Displacement Sensor 铜川KSE Pull Rod Displacement Sensor 铜川KSC Square Tube Miniature Self-reset Displacement sensor 铜川KSP Circular Tube Miniature Self-reset 铜川KTR11/12,KTR2 Spring Self-return Position Potentiometer 铜川KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 铜川KSN Self-resetting Displacement Sensor 铜川KFM Micro Slider Type Resistance Sensor 铜川WDL Rod Type Displacement Sensor 铜川KPF Flange Displacement Sensor 铜川KTM Miniature Pull Rod Displacement Sensor 铜川KPFZ Flange-mounted self-resetting resistance ruler 铜川KSD Linear Position Sensor 13FLP 铜川KST Self resetting displacement sensor 铜川KS8X Micro Self-resetting Displacement Sensor 铜川KSE Rod type displacement sensor 铜川KPM9 Mini Type Pull Rod Displacement Sensor 铜川LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 铜川KEP Brushless Sensor with Waterproof and Dustproof 铜川LEP displacement sensorwith Waterproof and dustproof
more+

铜川The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

铜川WS-S Pull Wire Displacement Sensor 铜川MPS-XL Pull Wire Displacement Sensor 铜川MPS-L Pull Wire Displacement Sensor 铜川MPS-L Magnetic Draw Wire Displacement Sensor 铜川MPSFS2-S Waterproof Absolute Wire Rope Sensor 铜川LPS-M Pull Wire Displacement Sensor 铜川LPS-S Pull Wire Displacement Sensor 铜川MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 铜川MPS-XS Magnetic Mounting Rope Displacement Sensor 铜川MPSFS2-M Waterproof Absolute Wire Rope Sensor 铜川MPS-XXXS Pull Wire Displacement Sensor 铜川MPS-XXS Pull Wire Displacement Sensor 铜川MPS-XS Pull Wire Displacement Sensor 铜川MPS-S Pull Wire Displacement Sensor 铜川MPS-M Pull Wire Displacement Sensor 铜川MDS-S Pull Wire Displacement Sensor 铜川SM-S Pull Wire Displacement Sensor 铜川WEP-S Pull Wire Displacement Sensor 铜川WEP-M Pull Wire Displacement Sensor 铜川SM-M Pull Wire Displacement Sensor 铜川MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 铜川MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 铜川MPSFS2-L Waterproof Absolute Wire Rope Sensor 铜川MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 铜川MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 铜川MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 铜川MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 铜川MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 铜川MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 铜川MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 铜川MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 铜川MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

铜川Spoke type weighing sensors《Special Customizable》

more+

铜川Three pulley tension sensor

more+

铜川Gap displacement sensor

more+

铜川Wireless data transmission radio/wireless transmission module

more+

铜川RS485 to USB converter

more+

铜川Wansung position sensor

more+

Digital Indicator

more+

铜川CH6 Displacement Display Instrument

more+

铜川XSA Digital Display Instrument

more+

铜川XSAW Potentiometer Digital Display Instrument

more+

铜川XSAEW Digital Display Instrument

more+

铜川XSEW Digital Display Instrument

more+

铜川XSK Digital Display Instrument

more+

铜川XSAE Displacement Sensor Digital Display Instrument

more+

铜川Fully Automatic Lubricating Oil Pump

Your current location is:Home>>铜川Product>>铜川Sensors>>铜川Transfer module and digital display instrument

铜川XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:570
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application