TEL:

189 8877 5298

Announcement:

Product

more+

邵阳Sensors

more+

Linear Position Sensor

邵阳KTC1/LWHPull Rod Linear Displacement Sensor 邵阳KTC2 Pull Rod Linear Displacement Sensor 邵阳KTF Slider Displacement Sensor 邵阳KTF1 Slider Displacement Sensor 邵阳KPC1 Articulated Electronic Ruler 邵阳KPC1H Hersman Plug out Pull-rod Resistance 邵阳KPM12R1/KPM12R2 Self-reset Resistance Sensor 邵阳KPM16 Shock Travel Sensor 邵阳KPM18 Small Articulated Resistance Sensor 邵阳KPM22 Small Articulated Resistance Sensor 邵阳KPM23 Small Articulated Resistance Sensor 邵阳KPM12 Shock Travel Sensor 邵阳WY-01 Resistive Displacement Sensor_COPY 邵阳WY-01 Resistive Displacement Sensor 邵阳KSE Pull Rod Displacement Sensor 邵阳KSC Square Tube Miniature Self-reset Displacement sensor 邵阳KSP Circular Tube Miniature Self-reset 邵阳KTR11/12,KTR2 Spring Self-return Position Potentiometer 邵阳KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 邵阳KSN Self-resetting Displacement Sensor 邵阳KFM Micro Slider Type Resistance Sensor 邵阳WDL Rod Type Displacement Sensor 邵阳KPF Flange Displacement Sensor 邵阳KTM Miniature Pull Rod Displacement Sensor 邵阳KPFZ Flange-mounted self-resetting resistance ruler 邵阳KSD Linear Position Sensor 13FLP 邵阳KST Self resetting displacement sensor 邵阳KS8X Micro Self-resetting Displacement Sensor 邵阳KSE Rod type displacement sensor 邵阳KPM9 Mini Type Pull Rod Displacement Sensor 邵阳LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 邵阳KEP Brushless Sensor with Waterproof and Dustproof 邵阳LEP displacement sensorwith Waterproof and dustproof
more+

邵阳The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

邵阳WS-S Pull Wire Displacement Sensor 邵阳MPS-XL Pull Wire Displacement Sensor 邵阳MPS-L Pull Wire Displacement Sensor 邵阳MPS-L Magnetic Draw Wire Displacement Sensor 邵阳MPSFS2-S Waterproof Absolute Wire Rope Sensor 邵阳LPS-M Pull Wire Displacement Sensor 邵阳LPS-S Pull Wire Displacement Sensor 邵阳MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 邵阳MPS-XS Magnetic Mounting Rope Displacement Sensor 邵阳MPSFS2-M Waterproof Absolute Wire Rope Sensor 邵阳MPS-XXXS Pull Wire Displacement Sensor 邵阳MPS-XXS Pull Wire Displacement Sensor 邵阳MPS-XS Pull Wire Displacement Sensor 邵阳MPS-S Pull Wire Displacement Sensor 邵阳MPS-M Pull Wire Displacement Sensor 邵阳MDS-S Pull Wire Displacement Sensor 邵阳SM-S Pull Wire Displacement Sensor 邵阳WEP-S Pull Wire Displacement Sensor 邵阳WEP-M Pull Wire Displacement Sensor 邵阳SM-M Pull Wire Displacement Sensor 邵阳MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 邵阳MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 邵阳MPSFS2-L Waterproof Absolute Wire Rope Sensor 邵阳MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 邵阳MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 邵阳MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 邵阳MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 邵阳MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 邵阳MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 邵阳MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 邵阳MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 邵阳MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

邵阳Spoke type weighing sensors《Special Customizable》

more+

邵阳Three pulley tension sensor

more+

邵阳Gap displacement sensor

more+

邵阳Wireless data transmission radio/wireless transmission module

more+

邵阳RS485 to USB converter

more+

邵阳Wansung position sensor

more+

Digital Indicator

more+

邵阳CH6 Displacement Display Instrument

more+

邵阳XSA Digital Display Instrument

more+

邵阳XSAW Potentiometer Digital Display Instrument

more+

邵阳XSAEW Digital Display Instrument

more+

邵阳XSEW Digital Display Instrument

more+

邵阳XSK Digital Display Instrument

more+

邵阳XSAE Displacement Sensor Digital Display Instrument

more+

邵阳Fully Automatic Lubricating Oil Pump

Your current location is:Home>>邵阳Product>>邵阳Sensors>>邵阳Transfer module and digital display instrument

邵阳XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:482
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application