TEL:

189 8877 5298

Announcement:

Product

more+

曲靖Sensors

more+

Linear Position Sensor

曲靖KTC1/LWHPull Rod Linear Displacement Sensor 曲靖KTC2 Pull Rod Linear Displacement Sensor 曲靖KTF Slider Displacement Sensor 曲靖KTF1 Slider Displacement Sensor 曲靖KPC1 Articulated Electronic Ruler 曲靖KPC1H Hersman Plug out Pull-rod Resistance 曲靖KPM12R1/KPM12R2 Self-reset Resistance Sensor 曲靖KPM16 Shock Travel Sensor 曲靖KPM18 Small Articulated Resistance Sensor 曲靖KPM22 Small Articulated Resistance Sensor 曲靖KPM23 Small Articulated Resistance Sensor 曲靖KPM12 Shock Travel Sensor 曲靖WY-01 Resistive Displacement Sensor_COPY 曲靖WY-01 Resistive Displacement Sensor 曲靖KSE Pull Rod Displacement Sensor 曲靖KSC Square Tube Miniature Self-reset Displacement sensor 曲靖KSP Circular Tube Miniature Self-reset 曲靖KTR11/12,KTR2 Spring Self-return Position Potentiometer 曲靖KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 曲靖KSN Self-resetting Displacement Sensor 曲靖KFM Micro Slider Type Resistance Sensor 曲靖WDL Rod Type Displacement Sensor 曲靖KPF Flange Displacement Sensor 曲靖KTM Miniature Pull Rod Displacement Sensor 曲靖KPFZ Flange-mounted self-resetting resistance ruler 曲靖KSD Linear Position Sensor 13FLP 曲靖KST Self resetting displacement sensor 曲靖KS8X Micro Self-resetting Displacement Sensor 曲靖KSE Rod type displacement sensor 曲靖KPM9 Mini Type Pull Rod Displacement Sensor 曲靖LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 曲靖KEP Brushless Sensor with Waterproof and Dustproof 曲靖LEP displacement sensorwith Waterproof and dustproof
more+

曲靖The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

曲靖WS-S Pull Wire Displacement Sensor 曲靖MPS-XL Pull Wire Displacement Sensor 曲靖MPS-L Pull Wire Displacement Sensor 曲靖MPS-L Magnetic Draw Wire Displacement Sensor 曲靖MPSFS2-S Waterproof Absolute Wire Rope Sensor 曲靖LPS-M Pull Wire Displacement Sensor 曲靖LPS-S Pull Wire Displacement Sensor 曲靖MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 曲靖MPS-XS Magnetic Mounting Rope Displacement Sensor 曲靖MPSFS2-M Waterproof Absolute Wire Rope Sensor 曲靖MPS-XXXS Pull Wire Displacement Sensor 曲靖MPS-XXS Pull Wire Displacement Sensor 曲靖MPS-XS Pull Wire Displacement Sensor 曲靖MPS-S Pull Wire Displacement Sensor 曲靖MPS-M Pull Wire Displacement Sensor 曲靖MDS-S Pull Wire Displacement Sensor 曲靖SM-S Pull Wire Displacement Sensor 曲靖WEP-S Pull Wire Displacement Sensor 曲靖WEP-M Pull Wire Displacement Sensor 曲靖SM-M Pull Wire Displacement Sensor 曲靖MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 曲靖MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 曲靖MPSFS2-L Waterproof Absolute Wire Rope Sensor 曲靖MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 曲靖MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 曲靖MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 曲靖MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 曲靖MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 曲靖MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 曲靖MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 曲靖MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 曲靖MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

曲靖Spoke type weighing sensors《Special Customizable》

more+

曲靖Three pulley tension sensor

more+

曲靖Gap displacement sensor

more+

曲靖Wireless data transmission radio/wireless transmission module

more+

曲靖RS485 to USB converter

more+

曲靖Wansung position sensor

more+

Digital Indicator

more+

曲靖CH6 Displacement Display Instrument

more+

曲靖XSA Digital Display Instrument

more+

曲靖XSAW Potentiometer Digital Display Instrument

more+

曲靖XSAEW Digital Display Instrument

more+

曲靖XSEW Digital Display Instrument

more+

曲靖XSK Digital Display Instrument

more+

曲靖XSAE Displacement Sensor Digital Display Instrument

more+

曲靖Fully Automatic Lubricating Oil Pump

Your current location is:Home>>曲靖Product>>曲靖Sensors>>曲靖Transfer module and digital display instrument

曲靖XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:556
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application