TEL:

189 8877 5298

Announcement:

Product

濮阳Sensors

more+

Linear Position Sensor

more+

濮阳KTC1/LWHPull Rod Linear Displacement Sensor 濮阳KTC2 Pull Rod Linear Displacement Sensor 濮阳KTF Slider Displacement Sensor 濮阳KTF1 Slider Displacement Sensor 濮阳KPC1 Articulated Electronic Ruler 濮阳KPC1H Hersman Plug out Pull-rod Resistance 濮阳KPM12R1/KPM12R2 Self-reset Resistance Sensor 濮阳KPM16 Shock Travel Sensor 濮阳KPM18 Small Articulated Resistance Sensor 濮阳KPM22 Small Articulated Resistance Sensor 濮阳KPM23 Small Articulated Resistance Sensor 濮阳KPM12 Shock Travel Sensor 濮阳WY-01 Resistive Displacement Sensor_COPY 濮阳WY-01 Resistive Displacement Sensor 濮阳KSE Pull Rod Displacement Sensor 濮阳KSC Square Tube Miniature Self-reset Displacement sensor 濮阳KSP Circular Tube Miniature Self-reset 濮阳KTR11/12,KTR2 Spring Self-return Position Potentiometer 濮阳KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 濮阳KSN Self-resetting Displacement Sensor 濮阳KFM Micro Slider Type Resistance Sensor 濮阳WDL Rod Type Displacement Sensor 濮阳KPF Flange Displacement Sensor 濮阳KTM Miniature Pull Rod Displacement Sensor 濮阳KPFZ Flange-mounted self-resetting resistance ruler 濮阳KSD Linear Position Sensor 13FLP 濮阳KST Self resetting displacement sensor 濮阳KS8X Micro Self-resetting Displacement Sensor 濮阳KSE Rod type displacement sensor 濮阳KPM9 Mini Type Pull Rod Displacement Sensor 濮阳LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 濮阳KEP Brushless Sensor with Waterproof and Dustproof 濮阳LEP displacement sensorwith Waterproof and dustproof
Rope/wire displacement sensor

more+

濮阳WS-S Pull Wire Displacement Sensor 濮阳MPS-XL Pull Wire Displacement Sensor 濮阳MPS-L Pull Wire Displacement Sensor 濮阳MPS-L Magnetic Draw Wire Displacement Sensor 濮阳MPSFS2-S Waterproof Absolute Wire Rope Sensor 濮阳LPS-M Pull Wire Displacement Sensor 濮阳LPS-S Pull Wire Displacement Sensor 濮阳MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 濮阳MPS-XS Magnetic Mounting Rope Displacement Sensor 濮阳MPSFS2-M Waterproof Absolute Wire Rope Sensor 濮阳MPS-XXXS Pull Wire Displacement Sensor 濮阳MPS-XXS Pull Wire Displacement Sensor 濮阳MPS-XS Pull Wire Displacement Sensor 濮阳MPS-S Pull Wire Displacement Sensor 濮阳MPS-M Pull Wire Displacement Sensor 濮阳MDS-S Pull Wire Displacement Sensor 濮阳SM-S Pull Wire Displacement Sensor 濮阳WEP-S Pull Wire Displacement Sensor 濮阳WEP-M Pull Wire Displacement Sensor 濮阳SM-M Pull Wire Displacement Sensor 濮阳MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 濮阳MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 濮阳MPSFS2-L Waterproof Absolute Wire Rope Sensor 濮阳MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 濮阳MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 濮阳MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 濮阳MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 濮阳MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 濮阳MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 濮阳MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 濮阳MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 濮阳MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
濮阳Fully Automatic Lubricating Oil Pump

more+

Your current location is:Home>>濮阳Product>>Digital Indicator>>濮阳XSEW Digital Display Instrument

濮阳XSEW Digital Instrument

  • Product classification:XSEW Digital Display Instrument
  • Number of views:714
  • QR code:
  • Release time:2023-11-14
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)



  • Application
Prev:no morer