TEL:

189 8877 5298

Announcement:

Product

more+

盘锦Sensors

more+

Linear Position Sensor

盘锦KTC1/LWHPull Rod Linear Displacement Sensor 盘锦KTC2 Pull Rod Linear Displacement Sensor 盘锦KTF Slider Displacement Sensor 盘锦KTF1 Slider Displacement Sensor 盘锦KPC1 Articulated Electronic Ruler 盘锦KPC1H Hersman Plug out Pull-rod Resistance 盘锦KPM12R1/KPM12R2 Self-reset Resistance Sensor 盘锦KPM16 Shock Travel Sensor 盘锦KPM18 Small Articulated Resistance Sensor 盘锦KPM22 Small Articulated Resistance Sensor 盘锦KPM23 Small Articulated Resistance Sensor 盘锦KPM12 Shock Travel Sensor 盘锦WY-01 Resistive Displacement Sensor_COPY 盘锦WY-01 Resistive Displacement Sensor 盘锦KSE Pull Rod Displacement Sensor 盘锦KSC Square Tube Miniature Self-reset Displacement sensor 盘锦KSP Circular Tube Miniature Self-reset 盘锦KTR11/12,KTR2 Spring Self-return Position Potentiometer 盘锦KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 盘锦KSN Self-resetting Displacement Sensor 盘锦KFM Micro Slider Type Resistance Sensor 盘锦WDL Rod Type Displacement Sensor 盘锦KPF Flange Displacement Sensor 盘锦KTM Miniature Pull Rod Displacement Sensor 盘锦KPFZ Flange-mounted self-resetting resistance ruler 盘锦KSD Linear Position Sensor 13FLP 盘锦KST Self resetting displacement sensor 盘锦KS8X Micro Self-resetting Displacement Sensor 盘锦KSE Rod type displacement sensor 盘锦KPM9 Mini Type Pull Rod Displacement Sensor 盘锦LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 盘锦KEP Brushless Sensor with Waterproof and Dustproof 盘锦LEP displacement sensorwith Waterproof and dustproof
more+

盘锦The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

盘锦WS-S Pull Wire Displacement Sensor 盘锦MPS-XL Pull Wire Displacement Sensor 盘锦MPS-L Pull Wire Displacement Sensor 盘锦MPS-L Magnetic Draw Wire Displacement Sensor 盘锦MPSFS2-S Waterproof Absolute Wire Rope Sensor 盘锦LPS-M Pull Wire Displacement Sensor 盘锦LPS-S Pull Wire Displacement Sensor 盘锦MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 盘锦MPS-XS Magnetic Mounting Rope Displacement Sensor 盘锦MPSFS2-M Waterproof Absolute Wire Rope Sensor 盘锦MPS-XXXS Pull Wire Displacement Sensor 盘锦MPS-XXS Pull Wire Displacement Sensor 盘锦MPS-XS Pull Wire Displacement Sensor 盘锦MPS-S Pull Wire Displacement Sensor 盘锦MPS-M Pull Wire Displacement Sensor 盘锦MDS-S Pull Wire Displacement Sensor 盘锦SM-S Pull Wire Displacement Sensor 盘锦WEP-S Pull Wire Displacement Sensor 盘锦WEP-M Pull Wire Displacement Sensor 盘锦SM-M Pull Wire Displacement Sensor 盘锦MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 盘锦MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 盘锦MPSFS2-L Waterproof Absolute Wire Rope Sensor 盘锦MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 盘锦MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 盘锦MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 盘锦MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 盘锦MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 盘锦MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 盘锦MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 盘锦MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 盘锦MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

盘锦Spoke type weighing sensors《Special Customizable》

more+

盘锦Three pulley tension sensor

more+

盘锦Gap displacement sensor

more+

盘锦Wireless data transmission radio/wireless transmission module

more+

盘锦RS485 to USB converter

more+

盘锦Wansung position sensor

more+

Digital Indicator

more+

盘锦CH6 Displacement Display Instrument

more+

盘锦XSA Digital Display Instrument

more+

盘锦XSAW Potentiometer Digital Display Instrument

more+

盘锦XSAEW Digital Display Instrument

more+

盘锦XSEW Digital Display Instrument

more+

盘锦XSK Digital Display Instrument

more+

盘锦XSAE Displacement Sensor Digital Display Instrument

more+

盘锦Fully Automatic Lubricating Oil Pump

Your current location is:Home>>盘锦Product>>盘锦Sensors>>Magnetostrictive displacement/liquid level sensor

盘锦MFTS Split-type Magnetostrictive Displacement Sensor

  • Product classification:Magnetostrictive displacement/liquid level sensor
  • Number of views:423
  • QR code:
  • Release time:2023-11-14
  • Overview

Overview of MFTS split-type magnetostrictive displacement sensor:


In ferromagnetic material, the change of magnetization direction will cause the change of dielectric lattice spacing, so that the length and volume of ferromagnetic material change, namely: magnetostriction phenomenon, also known as the Widman effect, and its inverse effect is known as the Villari effect.

The principle of magnetostrictive displacement sensor is to generate a strain pulse signal when two different magnetic fields intersect, and then calculate the time period required for this signal to be detected, so as to calculate the exact position. One comes from a permanent magnet in the ring and the other from an excitation pulse generated by an electronic component in the sensor's electronics chamber. The excitation pulse runs at the speed of sound along a waveguide wire made of magnetostrictive material inside the sensor. When intersecting with the permanent magnetic field in the magnetic ring, the mechanical vibration generated by the waveguide wire forms a strain pulse due to the magnetostriction phenomenon. The strain pulse is quickly detected by a sensing circuit in the electronic chamber. Multiply the total time from the moment the excitation pulse is generated until the strain pulse is detected by a fixed speed of sound, and we can accurately calculate the position change of the magnet. The process is continuous, so every time the position of the ring changes, a new position is quickly measured. Since the output signal is the true position value, rather than a proportional or re-amplified signal, there is no signal drift or change of value, let alone the need to periodically resold as with other sensors.

Magnetostrictive sensor is non-contact, never wear. It has the advantages of high resolution, high precision, high stability, high reliability, fast response time and long working life. Sensors do not need to be re-calibrated or regularly maintained.




Standard parameters of MFTS split-type magnetostrictive displacement sensor:


1. Range :50 ~ 5000mm

 

2. Supply voltage: +12VDC to +24VDC
 
3. Output form/analog signal: current 4-20mA and 0-20mA, voltage 0-5V and 0-10V, digital signal: RS485, MODBUS
 
4. Load capacity: voltage signal output load ≥4KΩ current signal output load ≤500Ω
 
5. Nonlinear error :≤0.05%FS
 
6 repeatability error :≤0.0005%FS
 
7 resolution :≤0.038mm
 
8. Hysteresis: acuities were 0.001% FS
 
9. Temperature stability: ≤0.002%/℃
 
10. Working current: ≤16mA
 
11. Working pressure: continuous working pressure ≤35MPa (MTL built-in high pressure series)
 
12. Operating temperature :T1: -20 ~ +55℃, T2: -40 ~ +80℃,
 
13. Measuring rod material: 0Cr18Ni9 (304) 316 stainless steel (special customization)
 
14. Electronic chamber shell material :0Cr18Ni9 (304) 316 stainless steel (special customization)
 
15. Lead mode: high temperature resistant twisted-pair shielded cable (default length: 1m, can also be provided according to user requirements)
 
16. Enclosure protection class: IP65

 

 



MFTS split-type magnetostrictive displacement sensor connection mode:

Before connecting cables, check whether the power supply meets the requirements of +24VDC and the output power must be greater than the total power consumption of the product. The output power of the power supply must be less than or equal to 95mA for each sensor in different range. If the power supply fails to meet requirements, replace the power supply to ensure that the sensor can work normally.
 

 

The output wiring mode of analog signal of split-type magnetostrictive displacement sensor of MFTS is as follows:

1. Direct outlet cable connection of waterproof connector:
The sensor has five contacts: positive power supply (brown), negative power supply (black), positive signal output (blue), negative signal output (white), shell ground (shielded wire)
 

2. Wiring mode of aviation plug:

The sensor has five contacts: ① positive power supply (brown), ② negative power supply (black), ③ positive signal output (blue), ④ negative signal output (white), ⑤ shell ground (shielded wire)

 
 

Digital signal output wiring mode of MFTS split-type magnetostrictive displacement sensor:

1. Direct outlet cable connection of waterproof connector:
 
The sensor has five contacts: positive power supply (brown), power supply ground (black), RS485A(blue), RS485B (white), shell ground (shielded wire)
 

2. Wiring mode of aviation plug:

The sensor has five contacts: ① positive power supply (brown), ② power supply ground (black), ③RS485A(blue), ④RS485B (white), ⑤ shell ground (shielded wire)

 

 

MFTS split-type magnetostrictive displacement sensor Application field:

Preset and feedback servo hydraulic oil cylinder piston position, preset and feedback servo cylinder piston position, position of grinding machines preset and feedback, casting forging machine tool preset position and feedback, provisioning and other machinery, such as gantry machine tool position feedback, boring machine, the position of shield machine, the coal mining machine oil cylinder presets and feedback, project promotion machine oil cylinder position presets and feedback, Rolling mill, such as steel mills and feedback, machine oil cylinder position preset provisioning and bottle blowing machine oil cylinder position feedback, injection molding machine oil cylinder position presets and feedback, the adjustment of the railways, Bridges, water level detection, sluice control, and feedback, wood mechanical position preset cylinder liquid level and feedback, the location of the preset chemical container liquid level and feedback, the location of the preset water and sewage treatment system, Geodetic system, gate opening position presetting and feedback, cylinder level measurement.

 


 

MFTS split-type magnetostrictive displacement sensor installation size diagram:


MFTS.jpg


Model Selection:

 

英文选型.jpg



  • Application