MRG-2232 (4L) Asynchronous motor
Self-control Grease and Thin Oil Lubrication Pump
Technical Parameters
Model | Voltage | Rated ritary Speed | Power | Current(A) | Rated pressure kgf/cm² | Max pressure kgf/cm² | Volume | Discharge capacity ml/min | Rated pressure kgf/cm² | Remarks |
MRG-2232-400TB | 220V 50/60HZ | 1350 | 25W | 0.22 | 20 | 40 | 4L | 200-300 CC/min | 30#~00# | MRG-2231代表 电压110V MRG-2232代表 电压220V |
MRG-2232-400XB | 220V 50/60HZ | |||||||||
MRG-2232-410XB | 220V 50/60HZ |
*Mode name with " T" is resistant, mode name with “X” is volumetric,without A is asynchronous motor
Method
1.Working time: press and hold the SET button, release it when the numbers jump, then press ▲ ▼ to set unit digit; and press the button of SET again, to set ten
digit with pressing ▲ ▼; press SET to hundreds digit(1~999 seconds).
2.Interval time: press and hold the SET button, release it when the numbers in other Display screen jump, then press ▲ ▼ to set unit digit; and press the button of
SET for two seconds, the interval time can shift between minutes and second(1~999 minutes or 1~999 seconds).
3.RST: Press and hold this key to relubricate or clear the abnormal alarm.
4.After the circuit power is turned on, the system belongs to the oil supply state, and enters the LUB, INT cycle. When the fuel is supply , the left LUB green light is
on, the right INT red light is on when the system is on rest.
5.When the ERO flashes, it means that the amount of oil is insufficient, and when the ERP flashes, it means that the pressure is abnormal.
6.There is no power-off memory function in the digital display box, and a small switch is turned on to enter the power-off memory. Turn off the small switch, and the
power off memory stops.
7.There is a key lock function in the digital display box. You can lock the set button after setting the time according to your needs.
(The lubrication program Can be customized according to customers’ requirements)