TEL:

189 8877 5298

Announcement:

Product

more+

南充Sensors

more+

Linear Position Sensor

南充KTC1/LWHPull Rod Linear Displacement Sensor 南充KTC2 Pull Rod Linear Displacement Sensor 南充KTF Slider Displacement Sensor 南充KTF1 Slider Displacement Sensor 南充KPC1 Articulated Electronic Ruler 南充KPC1H Hersman Plug out Pull-rod Resistance 南充KPM12R1/KPM12R2 Self-reset Resistance Sensor 南充KPM16 Shock Travel Sensor 南充KPM18 Small Articulated Resistance Sensor 南充KPM22 Small Articulated Resistance Sensor 南充KPM23 Small Articulated Resistance Sensor 南充KPM12 Shock Travel Sensor 南充WY-01 Resistive Displacement Sensor_COPY 南充WY-01 Resistive Displacement Sensor 南充KSE Pull Rod Displacement Sensor 南充KSC Square Tube Miniature Self-reset Displacement sensor 南充KSP Circular Tube Miniature Self-reset 南充KTR11/12,KTR2 Spring Self-return Position Potentiometer 南充KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 南充KSN Self-resetting Displacement Sensor 南充KFM Micro Slider Type Resistance Sensor 南充WDL Rod Type Displacement Sensor 南充KPF Flange Displacement Sensor 南充KTM Miniature Pull Rod Displacement Sensor 南充KPFZ Flange-mounted self-resetting resistance ruler 南充KSD Linear Position Sensor 13FLP 南充KST Self resetting displacement sensor 南充KS8X Micro Self-resetting Displacement Sensor 南充KSE Rod type displacement sensor 南充KPM9 Mini Type Pull Rod Displacement Sensor 南充LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 南充KEP Brushless Sensor with Waterproof and Dustproof 南充LEP displacement sensorwith Waterproof and dustproof
more+

南充The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

南充WS-S Pull Wire Displacement Sensor 南充MPS-XL Pull Wire Displacement Sensor 南充MPS-L Pull Wire Displacement Sensor 南充MPS-L Magnetic Draw Wire Displacement Sensor 南充MPSFS2-S Waterproof Absolute Wire Rope Sensor 南充LPS-M Pull Wire Displacement Sensor 南充LPS-S Pull Wire Displacement Sensor 南充MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 南充MPS-XS Magnetic Mounting Rope Displacement Sensor 南充MPSFS2-M Waterproof Absolute Wire Rope Sensor 南充MPS-XXXS Pull Wire Displacement Sensor 南充MPS-XXS Pull Wire Displacement Sensor 南充MPS-XS Pull Wire Displacement Sensor 南充MPS-S Pull Wire Displacement Sensor 南充MPS-M Pull Wire Displacement Sensor 南充MDS-S Pull Wire Displacement Sensor 南充SM-S Pull Wire Displacement Sensor 南充WEP-S Pull Wire Displacement Sensor 南充WEP-M Pull Wire Displacement Sensor 南充SM-M Pull Wire Displacement Sensor 南充MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 南充MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 南充MPSFS2-L Waterproof Absolute Wire Rope Sensor 南充MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 南充MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 南充MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 南充MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 南充MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 南充MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 南充MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 南充MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 南充MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

南充Spoke type weighing sensors《Special Customizable》

more+

南充Three pulley tension sensor

more+

南充Gap displacement sensor

more+

南充Wireless data transmission radio/wireless transmission module

more+

南充RS485 to USB converter

more+

南充Wansung position sensor

more+

Digital Indicator

more+

南充CH6 Displacement Display Instrument

more+

南充XSA Digital Display Instrument

more+

南充XSAW Potentiometer Digital Display Instrument

more+

南充XSAEW Digital Display Instrument

more+

南充XSEW Digital Display Instrument

more+

南充XSK Digital Display Instrument

more+

南充XSAE Displacement Sensor Digital Display Instrument

more+

南充Fully Automatic Lubricating Oil Pump

Your current location is:Home>>南充Product>>南充Sensors>>南充Transfer module and digital display instrument

南充XSEW Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:356
  • QR code:
  • Release time:2023-11-15
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)


单通道XSEW显示控制器数显表安装尺寸

Ⅵ、Single channel XSEW display controller Digit Instrument

Installation precautions
1 )Please avoid the installation in the following places: 

1.1:Because of the drastic temperature change, it may be exposed places
1.2:Places where corrosive gases and combustible gases are produced
1.3:Where direct vibration or may impact the product
1.4:Dust, salt, metal powder more places
1.5:Clutter interference, prone to static electricity, magnetic field, noise place

1.6: Air conditioning or heating air flow blowing directly to the place

1.7:  A place where the sunlight shines directly

1.8: Due to thermal radiation and other possible thermal accumulation of places

(2)  When installing, please consider the following points:
2.1:In order not to hinder heat dissipation, do not block the surroundings of this product, do not block the ventilation openings, and leave sufficient ventilation space.
2.2:Considering wiring and maintenance, please ensure there is more than 50mm of space above and below the instrument.
2.3:Please installing installation directly above the high heat meter (heater, transformer, semiconductor operator, high power resistance).
2.4:If the ambient temperature is above 50℃, please use a forced fan or a cooler, but do not let the cooling air blow directly to the instrument.
2.5:In order to improve noise resistance and safety, please keep away from high pressure machine, power line, power machine for installation.


Ⅵ:Single channel XSEW display controller digit instrument wiring precautions

In order to avoid the influence of noise interference, please keep the input signal line away from the instrument power line, power power line and load line.

Ensure that the instrument power supply is not affected by the noise of the power supply when wiring. Where noise is susceptible, use a noise filter.

- Please twist the wire material into a twist shape. The shorter the pitch of the twist, the better the noise defense effect.
- Be sure to install the noise filter on the ground disk surface, and minimize the wiring between the output side of the noise filter and the power terminal.
- Please do not install the fuse, switch, etc. on the output side of the noise filter, otherwise the effect of the filter will be reduced.

Note: There is no fuse inside this instrument. For fuse-required occasions, please set up separately: recommended fuse specifications:

- Rated voltage 250V, time delay fuse of rated current 1A

-  Please use the power supply that meets the power supply specification.

-  Please avoid mixing the interference in the measurement circuit

- The measurement circuit is separated from the power cord (power circuit) or the ground circuit.
- For the interference of static electricity, the use of shielding line effect is good.

- To prevent misoperation, please do not attach any wires to the unused terminals.


  • Application