TEL:

189 8877 5298

Announcement:

Product

绵阳Sensors

more+

Linear Position Sensor

more+

绵阳KTC1/LWHPull Rod Linear Displacement Sensor 绵阳KTC2 Pull Rod Linear Displacement Sensor 绵阳KTF Slider Displacement Sensor 绵阳KTF1 Slider Displacement Sensor 绵阳KPC1 Articulated Electronic Ruler 绵阳KPC1H Hersman Plug out Pull-rod Resistance 绵阳KPM12R1/KPM12R2 Self-reset Resistance Sensor 绵阳KPM16 Shock Travel Sensor 绵阳KPM18 Small Articulated Resistance Sensor 绵阳KPM22 Small Articulated Resistance Sensor 绵阳KPM23 Small Articulated Resistance Sensor 绵阳KPM12 Shock Travel Sensor 绵阳WY-01 Resistive Displacement Sensor_COPY 绵阳WY-01 Resistive Displacement Sensor 绵阳KSE Pull Rod Displacement Sensor 绵阳KSC Square Tube Miniature Self-reset Displacement sensor 绵阳KSP Circular Tube Miniature Self-reset 绵阳KTR11/12,KTR2 Spring Self-return Position Potentiometer 绵阳KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 绵阳KSN Self-resetting Displacement Sensor 绵阳KFM Micro Slider Type Resistance Sensor 绵阳WDL Rod Type Displacement Sensor 绵阳KPF Flange Displacement Sensor 绵阳KTM Miniature Pull Rod Displacement Sensor 绵阳KPFZ Flange-mounted self-resetting resistance ruler 绵阳KSD Linear Position Sensor 13FLP 绵阳KST Self resetting displacement sensor 绵阳KS8X Micro Self-resetting Displacement Sensor 绵阳KSE Rod type displacement sensor 绵阳KPM9 Mini Type Pull Rod Displacement Sensor 绵阳LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 绵阳KEP Brushless Sensor with Waterproof and Dustproof 绵阳LEP displacement sensorwith Waterproof and dustproof
Rope/wire displacement sensor

more+

绵阳WS-S Pull Wire Displacement Sensor 绵阳MPS-XL Pull Wire Displacement Sensor 绵阳MPS-L Pull Wire Displacement Sensor 绵阳MPS-L Magnetic Draw Wire Displacement Sensor 绵阳MPSFS2-S Waterproof Absolute Wire Rope Sensor 绵阳LPS-M Pull Wire Displacement Sensor 绵阳LPS-S Pull Wire Displacement Sensor 绵阳MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 绵阳MPS-XS Magnetic Mounting Rope Displacement Sensor 绵阳MPSFS2-M Waterproof Absolute Wire Rope Sensor 绵阳MPS-XXXS Pull Wire Displacement Sensor 绵阳MPS-XXS Pull Wire Displacement Sensor 绵阳MPS-XS Pull Wire Displacement Sensor 绵阳MPS-S Pull Wire Displacement Sensor 绵阳MPS-M Pull Wire Displacement Sensor 绵阳MDS-S Pull Wire Displacement Sensor 绵阳SM-S Pull Wire Displacement Sensor 绵阳WEP-S Pull Wire Displacement Sensor 绵阳WEP-M Pull Wire Displacement Sensor 绵阳SM-M Pull Wire Displacement Sensor 绵阳MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 绵阳MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 绵阳MPSFS2-L Waterproof Absolute Wire Rope Sensor 绵阳MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 绵阳MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 绵阳MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 绵阳MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 绵阳MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 绵阳MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 绵阳MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 绵阳MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 绵阳MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
绵阳Fully Automatic Lubricating Oil Pump

more+

Your current location is:Home>>绵阳Product>>绵阳Sensors>>绵阳LVDT differential transformer displacement sensor

绵阳Inductive frequency modulation displacement sensor

  • Product classification:LVDT differential transformer displacement sensor
  • Number of views:664
  • QR code:
  • Release time:2024-01-08
  • Overview

ML-F-50MM Inductive frequency modulation displacement sensor:


Application areas: Used on static load testers, in nuclear explosion tests, in geotechnical and in-situ testing, and in industrial and other fields.

         

Inductive frequency modulation displacement sensors can be widely used in national defense engineering scientific experiments, engineering survey and design geotechnical tests, and in-situ testing in various industries and industrial automation and measurement and control technology fields. Becoming an ideal choice for intelligent secondary instruments and supporting products in the microcomputer application department.

The inductive frequency modulation displacement sensor has excellent performance, using a convenient single power supply of 12V DC. The electronic circuit is sealed in a 304 stainless steel metal tube, and has waterproof, anti-corrosion, and explosion-proof properties.

电感调频式位移传感器



          

Characteristics of ML-F Inductive Frequency Modulation Displacement Sensor:

1. Outer diameter Φ 21mm, stainless steel 304 shell, rebound type.

2. Accurate detection: The repeatability and return error are very small, with errors less than 0.05%; The nonlinear error ranges from 0.1% to 1.0%. 3. Remote transmission does not affect testing accuracy and has high resolution.

4. Reliable in operation, due to its simple and compact structure, tight packaging, earthquake resistance and moisture resistance, it is particularly suitable for use in harsh environments.

5. Stable performance. Save power and cables


Technical parameters :


Stroke Length

50mm,100mm

Output Signal

Square wave signal with amplitude greater than 2V

Resolution

≤0.01MM

Linearity Error

0.1%---1.0%

Power Supply

12V DC

Working Current

≤5mA

Shock Resistance

250g/11ms

Vibration Tolerance

10g/2KHZ

Center frequency

16KHZ ±4%

Temperature Coefficient

Zero Point≤0.01%/℃

Allow cable length

≤1000 Meter

Operation temperature

-25℃~+85℃



Instructions for use:

1. Voltage and signal waveform: Power supply is 12V DC, square wave signal output

2. Installation: The sensor is fixed with a dial gauge holder or a magnetic gauge holder

3. Wiring: The sensor wire is a two core microphone wire, shielded as a ground wire, connected to the low terminal of the power and signal. One core wire is connected to the positive pole of the power supply, and the other is connected to the signal input terminal. The plug outputs, with one pin connected to the signal, two pins connected to the power supply, and three and four pins connected to the ground

4. The reading should be taken 30 minutes after power on

5. The factory comes with a 5-meter cable. If it is not enough, it should be declared in advance for extension

6. Properly protect, prevent falling, and strictly use according to technical conditions


Mechanical installation dimensions :



电感调频式位移传感器



Miran displacement sensor calibration table

Sensor model: ML-F-50MM

① Within the range of -10~50 ℃, the average frequency drift per degree is 0.1Hz/℃

② Frequency drift of 1Hz for 4 hours at room temperature of 20 ℃

③ Rating Results Table