TEL:

189 8877 5298

Announcement:

Product

more+

廊坊Sensors

more+

Linear Position Sensor

廊坊KTC1/LWHPull Rod Linear Displacement Sensor 廊坊KTC2 Pull Rod Linear Displacement Sensor 廊坊KTF Slider Displacement Sensor 廊坊KTF1 Slider Displacement Sensor 廊坊KPC1 Articulated Electronic Ruler 廊坊KPC1H Hersman Plug out Pull-rod Resistance 廊坊KPM12R1/KPM12R2 Self-reset Resistance Sensor 廊坊KPM16 Shock Travel Sensor 廊坊KPM18 Small Articulated Resistance Sensor 廊坊KPM22 Small Articulated Resistance Sensor 廊坊KPM23 Small Articulated Resistance Sensor 廊坊KPM12 Shock Travel Sensor 廊坊WY-01 Resistive Displacement Sensor_COPY 廊坊WY-01 Resistive Displacement Sensor 廊坊KSE Pull Rod Displacement Sensor 廊坊KSC Square Tube Miniature Self-reset Displacement sensor 廊坊KSP Circular Tube Miniature Self-reset 廊坊KTR11/12,KTR2 Spring Self-return Position Potentiometer 廊坊KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 廊坊KSN Self-resetting Displacement Sensor 廊坊KFM Micro Slider Type Resistance Sensor 廊坊WDL Rod Type Displacement Sensor 廊坊KPF Flange Displacement Sensor 廊坊KTM Miniature Pull Rod Displacement Sensor 廊坊KPFZ Flange-mounted self-resetting resistance ruler 廊坊KSD Linear Position Sensor 13FLP 廊坊KST Self resetting displacement sensor 廊坊KS8X Micro Self-resetting Displacement Sensor 廊坊KSE Rod type displacement sensor 廊坊KPM9 Mini Type Pull Rod Displacement Sensor 廊坊LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 廊坊KEP Brushless Sensor with Waterproof and Dustproof 廊坊LEP displacement sensorwith Waterproof and dustproof
more+

廊坊The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

廊坊WS-S Pull Wire Displacement Sensor 廊坊MPS-XL Pull Wire Displacement Sensor 廊坊MPS-L Pull Wire Displacement Sensor 廊坊MPS-L Magnetic Draw Wire Displacement Sensor 廊坊MPSFS2-S Waterproof Absolute Wire Rope Sensor 廊坊LPS-M Pull Wire Displacement Sensor 廊坊LPS-S Pull Wire Displacement Sensor 廊坊MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 廊坊MPS-XS Magnetic Mounting Rope Displacement Sensor 廊坊MPSFS2-M Waterproof Absolute Wire Rope Sensor 廊坊MPS-XXXS Pull Wire Displacement Sensor 廊坊MPS-XXS Pull Wire Displacement Sensor 廊坊MPS-XS Pull Wire Displacement Sensor 廊坊MPS-S Pull Wire Displacement Sensor 廊坊MPS-M Pull Wire Displacement Sensor 廊坊MDS-S Pull Wire Displacement Sensor 廊坊SM-S Pull Wire Displacement Sensor 廊坊WEP-S Pull Wire Displacement Sensor 廊坊WEP-M Pull Wire Displacement Sensor 廊坊SM-M Pull Wire Displacement Sensor 廊坊MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 廊坊MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 廊坊MPSFS2-L Waterproof Absolute Wire Rope Sensor 廊坊MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 廊坊MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 廊坊MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 廊坊MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 廊坊MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 廊坊MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 廊坊MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 廊坊MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 廊坊MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

廊坊Spoke type weighing sensors《Special Customizable》

more+

廊坊Three pulley tension sensor

more+

廊坊Gap displacement sensor

more+

廊坊Wireless data transmission radio/wireless transmission module

more+

廊坊RS485 to USB converter

more+

廊坊Wansung position sensor

more+

Digital Indicator

more+

廊坊CH6 Displacement Display Instrument

more+

廊坊XSA Digital Display Instrument

more+

廊坊XSAW Potentiometer Digital Display Instrument

more+

廊坊XSAEW Digital Display Instrument

more+

廊坊XSEW Digital Display Instrument

more+

廊坊XSK Digital Display Instrument

more+

廊坊XSAE Displacement Sensor Digital Display Instrument

more+

廊坊Fully Automatic Lubricating Oil Pump

Your current location is:Home>>廊坊Product>>廊坊Sensors>>廊坊Transfer module and digital display instrument

廊坊XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:427
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application