TEL:

189 8877 5298

Announcement:

Product

济源Sensors

more+

Linear Position Sensor

more+

济源KTC1/LWHPull Rod Linear Displacement Sensor 济源KTC2 Pull Rod Linear Displacement Sensor 济源KTF Slider Displacement Sensor 济源KTF1 Slider Displacement Sensor 济源KPC1 Articulated Electronic Ruler 济源KPC1H Hersman Plug out Pull-rod Resistance 济源KPM12R1/KPM12R2 Self-reset Resistance Sensor 济源KPM16 Shock Travel Sensor 济源KPM18 Small Articulated Resistance Sensor 济源KPM22 Small Articulated Resistance Sensor 济源KPM23 Small Articulated Resistance Sensor 济源KPM12 Shock Travel Sensor 济源WY-01 Resistive Displacement Sensor_COPY 济源WY-01 Resistive Displacement Sensor 济源KSE Pull Rod Displacement Sensor 济源KSC Square Tube Miniature Self-reset Displacement sensor 济源KSP Circular Tube Miniature Self-reset 济源KTR11/12,KTR2 Spring Self-return Position Potentiometer 济源KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 济源KSN Self-resetting Displacement Sensor 济源KFM Micro Slider Type Resistance Sensor 济源WDL Rod Type Displacement Sensor 济源KPF Flange Displacement Sensor 济源KTM Miniature Pull Rod Displacement Sensor 济源KPFZ Flange-mounted self-resetting resistance ruler 济源KSD Linear Position Sensor 13FLP 济源KST Self resetting displacement sensor 济源KS8X Micro Self-resetting Displacement Sensor 济源KSE Rod type displacement sensor 济源KPM9 Mini Type Pull Rod Displacement Sensor 济源LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 济源KEP Brushless Sensor with Waterproof and Dustproof 济源LEP displacement sensorwith Waterproof and dustproof
Rope/wire displacement sensor

more+

济源WS-S Pull Wire Displacement Sensor 济源MPS-XL Pull Wire Displacement Sensor 济源MPS-L Pull Wire Displacement Sensor 济源MPS-L Magnetic Draw Wire Displacement Sensor 济源MPSFS2-S Waterproof Absolute Wire Rope Sensor 济源LPS-M Pull Wire Displacement Sensor 济源LPS-S Pull Wire Displacement Sensor 济源MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 济源MPS-XS Magnetic Mounting Rope Displacement Sensor 济源MPSFS2-M Waterproof Absolute Wire Rope Sensor 济源MPS-XXXS Pull Wire Displacement Sensor 济源MPS-XXS Pull Wire Displacement Sensor 济源MPS-XS Pull Wire Displacement Sensor 济源MPS-S Pull Wire Displacement Sensor 济源MPS-M Pull Wire Displacement Sensor 济源MDS-S Pull Wire Displacement Sensor 济源SM-S Pull Wire Displacement Sensor 济源WEP-S Pull Wire Displacement Sensor 济源WEP-M Pull Wire Displacement Sensor 济源SM-M Pull Wire Displacement Sensor 济源MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 济源MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 济源MPSFS2-L Waterproof Absolute Wire Rope Sensor 济源MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 济源MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 济源MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 济源MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 济源MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 济源MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 济源MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 济源MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 济源MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
济源Fully Automatic Lubricating Oil Pump

more+

Your current location is:Home>>济源Product>>济源Sensors>>Fixed inclinometer sensor

济源Fixed inclinometer sensor

  • Product classification:Fixed inclinometer sensor
  • Number of views:653
  • QR code:
  • Release time:2024-02-27
  • Overview

1    Principle and overview of fixed inclinometer/inclinometer:

       The fixed inclinometer is a fixed inclinometer developed by our company based on high-precision six axis sensors combined with single-chip embedded systems. It is used to observe the relative horizontal biaxial tilt angle of slopes, foundation pits, railways, etc., and combined with automatic real-time monitoring systems, it can also be suitable for long-term monitoring of landslide geological activities. The multi-level setting of drilling can measure the inclination angle of each depth, convert the inclination angle into displacement, and is suitable for the deformation variables of concealed parts that are difficult to observe by conventional measurement methods.
1708929777599201[1].png

           The fixed inclinometer is composed of an electronic compartment (high-precision angle sensitive components and chipset), as well as  external stainless steel components, pulley components, etc. An external four core shielded wire leads out. Usually, the installation of fixed inclinometers also requires the installation of accessories, such as inclinometers, stainless steel wires, lifting rings, etc., which need to be configured reasonably according to the on-site situation.
1708930027219730[1].png



2    Technical parameters of fixed inclinometer/inclinometer:


Item

Parameter

Voltage Supply

+9V--28VDC

Working Current

14mA(+24VDC)

Working Temperature

-20℃--80℃

Testing Range

XY Dual Axis ±60°

Resolution ratio

0.01°

Accuracy

±0.05°

Output Signal

RS485

Protocol

Modbus—RTU

Guide wheels distance

500mm

Cable Length

2m default


Wiring Definition

Brown:Supply(+)

Black:Supply(-)

Blue:458(A)

White:485(B)



3   Product Naming Rules


企业微信截图_17089312124177.png


             Under actual installation conditions, the direction of the guide wheel (i.e. the X-axis direction) should be installed towards the expected tilt direction. After the inclinometer is placed in the designated position of the inclinometer tube, the initial angle value needs to be determined. After installation, read the current angle value of the inclinometer. After the data stabilizes, take the average of the current position angle as the initial angle value of the sensor, denoted as Angle_X0, Angle_Y0. Afterwards, the angle values of all sensors are calculated based on this initial angle value.

            The horizontal displacement of the initial value in the X-axis direction is represented by DX0, the displacement in the y-axis direction is represented by DY0, and the overall displacement is represented by D0. The angle data measured by sensors, Angle_X and Angle_Y, are calculated using a trigonometric function at the gauge length L (i.e. the wheelbase before adjacent sensors) to obtain the horizontal displacement at the measured gauge length. The displacement direction is based on the sign of the angle data measured on the X and Y axes, with+indicating positive direction and - indicating negative direction. In practical use, data analysis is conducted based on relative displacement, which refers to the displacement of each measurement point relative to its initial position. Reference for displacement calculation method :


Displacement in initial direction of  X-axis :  DX0 = L*sin(Angle_X0)

Displacement in initial direction of  Y-axis :  DY0 = L*sin(Angle_Y0)

Overall displacement at initial position :   D0 = (DX0²+DY0)½


Horizontal displacement in the X-axis direction :  DXn = L*sin(Angle_Xn)

Relative displacement in the X-axis direction :  △DXn = DXn - DX0


Horizontal displacement in the Y-axis direction :  DYn = L*sin(Angle_Yn)

Relative displacement in the Y-axis direction :  △DYn = DYn - DY0





  • Application
Prev:no morer