TEL:

180 3818 6775

Announcement:

Product

海北Sensors

more+

Linear Position Sensor

more+

海北KTC11 Pull Rod Linear Displacement Sensor 海北KTC1/LWHPull Rod Linear Displacement Sensor 海北KTF Slider Displacement Sensor 海北KTC2/KTC21 Pull Rod Linear Displacement Sensor 海北KTF1 Slider Displacement Sensor 海北KTR11/12,KTR2 Spring Self-return Position Potentiometer 海北KTM Miniature Pull Rod Displacement Sensor 海北KTR3/KTR4 Spring Self-return Position Potentiometer 海北TR Spring Self-return Position Potentiometer 海北KPC1H Hersman Plug out Pull-rod Resistance 海北KPC1 Articulated Electronic Ruler 海北KPM23 Small Articulated Resistance Sensor 海北KPM22 Small Articulated Resistance Sensor 海北KPM18 Small Articulated Resistance Sensor 海北KPM16 Shock Travel Sensor 海北KPM12 Shock Travel Sensor 海北KPM12R1/KPM12R2 Self-reset Resistance Sensor 海北WY-01 Resistive Displacement Sensor 海北WDL Rod Type Displacement Sensor 海北KSE Pull Rod Displacement Sensor 海北KPF Flange Displacement Sensor 海北KFM Micro Slider Type Resistance Sensor 海北KSP Circular Tube Miniature Self-reset 海北KSC Square Tube Miniature Self-reset Displacement sensor 海北KS8X Micro Self-resetting Displacement Sensor 海北KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 海北KST Self resetting displacement sensor 海北KSD Linear Position Sensor 13FLP 海北KPFZ Flange-mounted self-resetting resistance ruler 海北LEP displacement sensorwith Waterproof and dustproof 海北KEP Brushless Sensor with Waterproof and Dustproof 海北LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 海北KPM9 Mini Type Pull Rod Displacement Sensor 海北KSE Rod type displacement sensor 海北KSF Micro Slide Type Displacement Sensor 海北KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

海北MPS-XXXS Pull Wire Displacement Sensor 海北MPS-XXS Pull Wire Displacement Sensor 海北MPS-XS Pull Wire Displacement Sensor 海北MPS-S Pull Wire Displacement Sensor 海北MPS-M Pull Wire Displacement Sensor 海北MPS-L Pull Wire Displacement Sensor 海北MPS-XL Pull Wire Displacement Sensor 海北MPSFS2-S Waterproof Absolute Wire Rope Sensor 海北MPSFS2-M Waterproof Absolute Wire Rope Sensor 海北MPSFS2-L Waterproof Absolute Wire Rope Sensor 海北MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 海北MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 海北MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 海北MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 海北MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 海北MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 海北MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 海北MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 海北MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 海北SM-S Pull Wire Displacement Sensor 海北SM-M Pull Wire Displacement Sensor 海北WEP-S Pull Wire Displacement Sensor 海北WEP-M Pull Wire Displacement Sensor 海北WS-S Pull Wire Displacement Sensor 海北MDS-S Pull Wire Displacement Sensor 海北MPS-XS Magnetic Mounting Rope Displacement Sensor 海北MPS-L Magnetic Draw Wire Displacement Sensor 海北MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 海北MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 海北MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Magnetostrictive displacement/liquid level sensor

more+

海北Fully Automatic Lubricating Oil Pump

more+

海北Electric Automatic Oil Pump / Manual Oil Pump

more+

海北MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 海北MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 海北MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 海北MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 海北MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 海北MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 海北MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 海北MGH-1205-100T Semi-automatic Butter Lubrication Pump 海北MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 海北MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 海北MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 海北MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 海北MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 海北MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 海北MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 海北MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 海北MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 海北MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 海北MRH-1202-100T Semi-automatic Grease Lubrication Pump 海北MRH-1232-100TB Automatical Grease Lubrication Pump 海北MGH-1202-100T Semi-automatic Butter Lubrication Pump 海北MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>海北Product>>Digital Indicator>>海北XSEW Digital Display Instrument

海北XSEW Digital Instrument

  • Product classification:XSEW Digital Display Instrument
  • Number of views:2305
  • QR code:
  • Release time:2023-11-14
  • Overview

XSEW Digital Display Instrument

0.05 level precision, measurement and control speed of 10 ~400 times per second can be set
Display range-99999~99999
Analog quantity is universal input, selected by setting
The 1-4-point alarm output is optional. It includes seven basic alarm methods, including measurement upper limit, measurement lower limit, deviation upper limit, deviation upper limit, deviation absolute value lower limit, fault alarm and four standby alarm methods.(Standby alarm mode: when the measured value is in the output interval, when the measured value enters the non-output interval, then the normal alarm)
Higher degree of standardization, rich functions. Including: input signal fault processing, measurement value clearance, peak, valley value acquisition, 10 section broken line correction and other functions
Optional transmission, communication

content

Code description

XSEW-

0.05 level measurement accuracy;Measurement and control speed is 10 times per second

Dimension

AH

160×80×125      Hole Size:152×76 (Note①)

CH

96×48×82       Hole Size:92×45 (Note②)

 

Panel specifications


Single 6-digit LED display

 Alarm(option)(250V AC/3A,resistive load)

AH

T1~T4

1~4 point relay output, are normally open and closed double contacts

 

01~04

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

CH

T1~T2

1~2 point relay output, are normally open and closed double contacts

01~02

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

T3

3 point relay output is a single open contact.

03

Alarm is OC door output (voltage should be less than 40VDC and current should be less than 40 mA)

Contact input (optional)

K

1 point external switch quantity input for reset

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)(Suitable for the measurement and control speed of 200 times per second and above the transmission speed)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

 

Voltage output (-5V-+5V)

A5

Voltage output (-10V-10V)

Quick delivery (optional)

F

Suitable for the measurement and control speed of 200 times per second and above the transmission speed

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option)

(Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol)

S1

RS232 interface (only AH size)

S2

RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note①:A size instrument

When selecting 1-point switching input, the instrument’s transmission output and communication functions can only be selected from one of the two.
Note②:C size instrument
When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (communication only supports RS485 at this time)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)



  • Application
Prev:no morer