TEL:

189 8877 5298

Announcement:

Product

more+

福建Sensors

more+

Linear Position Sensor

福建KTC1/LWHPull Rod Linear Displacement Sensor 福建KTC2 Pull Rod Linear Displacement Sensor 福建KTF Slider Displacement Sensor 福建KTF1 Slider Displacement Sensor 福建KPC1 Articulated Electronic Ruler 福建KPC1H Hersman Plug out Pull-rod Resistance 福建KPM12R1/KPM12R2 Self-reset Resistance Sensor 福建KPM16 Shock Travel Sensor 福建KPM18 Small Articulated Resistance Sensor 福建KPM22 Small Articulated Resistance Sensor 福建KPM23 Small Articulated Resistance Sensor 福建KPM12 Shock Travel Sensor 福建WY-01 Resistive Displacement Sensor_COPY 福建WY-01 Resistive Displacement Sensor 福建KSE Pull Rod Displacement Sensor 福建KSC Square Tube Miniature Self-reset Displacement sensor 福建KSP Circular Tube Miniature Self-reset 福建KTR11/12,KTR2 Spring Self-return Position Potentiometer 福建KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 福建KSN Self-resetting Displacement Sensor 福建KFM Micro Slider Type Resistance Sensor 福建WDL Rod Type Displacement Sensor 福建KPF Flange Displacement Sensor 福建KTM Miniature Pull Rod Displacement Sensor 福建KPFZ Flange-mounted self-resetting resistance ruler 福建KSD Linear Position Sensor 13FLP 福建KST Self resetting displacement sensor 福建KS8X Micro Self-resetting Displacement Sensor 福建KSE Rod type displacement sensor 福建KPM9 Mini Type Pull Rod Displacement Sensor 福建LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 福建KEP Brushless Sensor with Waterproof and Dustproof 福建LEP displacement sensorwith Waterproof and dustproof
more+

福建The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

福建WS-S Pull Wire Displacement Sensor 福建MPS-XL Pull Wire Displacement Sensor 福建MPS-L Pull Wire Displacement Sensor 福建MPS-L Magnetic Draw Wire Displacement Sensor 福建MPSFS2-S Waterproof Absolute Wire Rope Sensor 福建LPS-M Pull Wire Displacement Sensor 福建LPS-S Pull Wire Displacement Sensor 福建MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 福建MPS-XS Magnetic Mounting Rope Displacement Sensor 福建MPSFS2-M Waterproof Absolute Wire Rope Sensor 福建MPS-XXXS Pull Wire Displacement Sensor 福建MPS-XXS Pull Wire Displacement Sensor 福建MPS-XS Pull Wire Displacement Sensor 福建MPS-S Pull Wire Displacement Sensor 福建MPS-M Pull Wire Displacement Sensor 福建MDS-S Pull Wire Displacement Sensor 福建SM-S Pull Wire Displacement Sensor 福建WEP-S Pull Wire Displacement Sensor 福建WEP-M Pull Wire Displacement Sensor 福建SM-M Pull Wire Displacement Sensor 福建MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 福建MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 福建MPSFS2-L Waterproof Absolute Wire Rope Sensor 福建MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 福建MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 福建MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 福建MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 福建MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 福建MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 福建MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 福建MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 福建MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

福建Spoke type weighing sensors《Special Customizable》

more+

福建Three pulley tension sensor

more+

福建Gap displacement sensor

more+

福建Wireless data transmission radio/wireless transmission module

more+

福建RS485 to USB converter

more+

福建Wansung position sensor

more+

Digital Indicator

more+

福建CH6 Displacement Display Instrument

more+

福建XSA Digital Display Instrument

more+

福建XSAW Potentiometer Digital Display Instrument

more+

福建XSAEW Digital Display Instrument

more+

福建XSEW Digital Display Instrument

more+

福建XSK Digital Display Instrument

more+

福建XSAE Displacement Sensor Digital Display Instrument

more+

福建Fully Automatic Lubricating Oil Pump

Your current location is:Home>>福建Product>>福建Sensors>>福建Transfer module and digital display instrument

福建XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:623
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application