德阳KTC1/LWHPull Rod Linear Displacement Sensor 德阳KTC2 Pull Rod Linear Displacement Sensor 德阳KTF Slider Displacement Sensor 德阳KTF1 Slider Displacement Sensor 德阳KPC1 Articulated Electronic Ruler 德阳KPC1H Hersman Plug out Pull-rod Resistance 德阳KPM12R1/KPM12R2 Self-reset Resistance Sensor 德阳KPM16 Shock Travel Sensor 德阳KPM18 Small Articulated Resistance Sensor 德阳KPM22 Small Articulated Resistance Sensor 德阳KPM23 Small Articulated Resistance Sensor 德阳KPM12 Shock Travel Sensor 德阳WY-01 Resistive Displacement Sensor_COPY 德阳WY-01 Resistive Displacement Sensor 德阳KSE Pull Rod Displacement Sensor 德阳KSC Square Tube Miniature Self-reset Displacement sensor 德阳KSP Circular Tube Miniature Self-reset 德阳KTR11/12,KTR2 Spring Self-return Position Potentiometer 德阳KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 德阳KSN Self-resetting Displacement Sensor 德阳KFM Micro Slider Type Resistance Sensor 德阳WDL Rod Type Displacement Sensor 德阳KPF Flange Displacement Sensor 德阳KTM Miniature Pull Rod Displacement Sensor 德阳KPFZ Flange-mounted self-resetting resistance ruler 德阳KSD Linear Position Sensor 13FLP 德阳KST Self resetting displacement sensor 德阳KS8X Micro Self-resetting Displacement Sensor 德阳KSE Rod type displacement sensor 德阳KPM9 Mini Type Pull Rod Displacement Sensor 德阳LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 德阳KEP Brushless Sensor with Waterproof and Dustproof 德阳LEP displacement sensorwith Waterproof and dustproof
Rope/wire displacement sensor

more+

德阳WS-S Pull Wire Displacement Sensor 德阳MPS-XL Pull Wire Displacement Sensor 德阳MPS-L Pull Wire Displacement Sensor 德阳MPS-L Magnetic Draw Wire Displacement Sensor 德阳MPSFS2-S Waterproof Absolute Wire Rope Sensor 德阳LPS-M Pull Wire Displacement Sensor 德阳LPS-S Pull Wire Displacement Sensor 德阳MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 德阳MPS-XS Magnetic Mounting Rope Displacement Sensor 德阳MPSFS2-M Waterproof Absolute Wire Rope Sensor 德阳MPS-XXXS Pull Wire Displacement Sensor 德阳MPS-XXS Pull Wire Displacement Sensor 德阳MPS-XS Pull Wire Displacement Sensor 德阳MPS-S Pull Wire Displacement Sensor 德阳MPS-M Pull Wire Displacement Sensor 德阳MDS-S Pull Wire Displacement Sensor 德阳SM-S Pull Wire Displacement Sensor 德阳WEP-S Pull Wire Displacement Sensor 德阳WEP-M Pull Wire Displacement Sensor 德阳SM-M Pull Wire Displacement Sensor 德阳MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 德阳MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 德阳MPSFS2-L Waterproof Absolute Wire Rope Sensor 德阳MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 德阳MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 德阳MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 德阳MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德阳MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德阳MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德阳MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德阳MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 德阳MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
德阳Fully Automatic Lubricating Oil Pump

more+

Your current location is:Home>>德阳Product>>德阳Sensors>>德阳Transfer module and digital display instrument

德阳XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:688
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)