TEL:

189 8877 5298

Announcement:

Product

more+

楚雄Sensors

more+

Linear Position Sensor

楚雄KTC1/LWHPull Rod Linear Displacement Sensor 楚雄KTC2 Pull Rod Linear Displacement Sensor 楚雄KTF Slider Displacement Sensor 楚雄KTF1 Slider Displacement Sensor 楚雄KPC1 Articulated Electronic Ruler 楚雄KPC1H Hersman Plug out Pull-rod Resistance 楚雄KPM12R1/KPM12R2 Self-reset Resistance Sensor 楚雄KPM16 Shock Travel Sensor 楚雄KPM18 Small Articulated Resistance Sensor 楚雄KPM22 Small Articulated Resistance Sensor 楚雄KPM23 Small Articulated Resistance Sensor 楚雄KPM12 Shock Travel Sensor 楚雄WY-01 Resistive Displacement Sensor_COPY 楚雄WY-01 Resistive Displacement Sensor 楚雄KSE Pull Rod Displacement Sensor 楚雄KSC Square Tube Miniature Self-reset Displacement sensor 楚雄KSP Circular Tube Miniature Self-reset 楚雄KTR11/12,KTR2 Spring Self-return Position Potentiometer 楚雄KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 楚雄KSN Self-resetting Displacement Sensor 楚雄KFM Micro Slider Type Resistance Sensor 楚雄WDL Rod Type Displacement Sensor 楚雄KPF Flange Displacement Sensor 楚雄KTM Miniature Pull Rod Displacement Sensor 楚雄KPFZ Flange-mounted self-resetting resistance ruler 楚雄KSD Linear Position Sensor 13FLP 楚雄KST Self resetting displacement sensor 楚雄KS8X Micro Self-resetting Displacement Sensor 楚雄KSE Rod type displacement sensor 楚雄KPM9 Mini Type Pull Rod Displacement Sensor 楚雄LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 楚雄KEP Brushless Sensor with Waterproof and Dustproof 楚雄LEP displacement sensorwith Waterproof and dustproof
more+

楚雄The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

楚雄WS-S Pull Wire Displacement Sensor 楚雄MPS-XL Pull Wire Displacement Sensor 楚雄MPS-L Pull Wire Displacement Sensor 楚雄MPS-L Magnetic Draw Wire Displacement Sensor 楚雄MPSFS2-S Waterproof Absolute Wire Rope Sensor 楚雄LPS-M Pull Wire Displacement Sensor 楚雄LPS-S Pull Wire Displacement Sensor 楚雄MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 楚雄MPS-XS Magnetic Mounting Rope Displacement Sensor 楚雄MPSFS2-M Waterproof Absolute Wire Rope Sensor 楚雄MPS-XXXS Pull Wire Displacement Sensor 楚雄MPS-XXS Pull Wire Displacement Sensor 楚雄MPS-XS Pull Wire Displacement Sensor 楚雄MPS-S Pull Wire Displacement Sensor 楚雄MPS-M Pull Wire Displacement Sensor 楚雄MDS-S Pull Wire Displacement Sensor 楚雄SM-S Pull Wire Displacement Sensor 楚雄WEP-S Pull Wire Displacement Sensor 楚雄WEP-M Pull Wire Displacement Sensor 楚雄SM-M Pull Wire Displacement Sensor 楚雄MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 楚雄MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 楚雄MPSFS2-L Waterproof Absolute Wire Rope Sensor 楚雄MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 楚雄MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 楚雄MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 楚雄MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 楚雄MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 楚雄MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 楚雄MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 楚雄MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 楚雄MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

楚雄Spoke type weighing sensors《Special Customizable》

more+

楚雄Three pulley tension sensor

more+

楚雄Gap displacement sensor

more+

楚雄Wireless data transmission radio/wireless transmission module

more+

楚雄RS485 to USB converter

more+

楚雄Wansung position sensor

more+

Digital Indicator

more+

楚雄CH6 Displacement Display Instrument

more+

楚雄XSA Digital Display Instrument

more+

楚雄XSAW Potentiometer Digital Display Instrument

more+

楚雄XSAEW Digital Display Instrument

more+

楚雄XSEW Digital Display Instrument

more+

楚雄XSK Digital Display Instrument

more+

楚雄XSAE Displacement Sensor Digital Display Instrument

more+

楚雄Fully Automatic Lubricating Oil Pump

Your current location is:Home>>楚雄Product>>楚雄Sensors>>楚雄Transfer module and digital display instrument

楚雄XSK Display controller digital display (single channel)

  • Product classification:Transfer module and digital display instrument
  • Number of views:426
  • QR code:
  • Release time:2023-11-15
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)



  • Application