TEL:

189 8877 5298

Announcement:

Product

more+

长沙Sensors

more+

Linear Position Sensor

长沙KTC1/LWHPull Rod Linear Displacement Sensor 长沙KTC2 Pull Rod Linear Displacement Sensor 长沙KTF Slider Displacement Sensor 长沙KTF1 Slider Displacement Sensor 长沙KPC1 Articulated Electronic Ruler 长沙KPC1H Hersman Plug out Pull-rod Resistance 长沙KPM12R1/KPM12R2 Self-reset Resistance Sensor 长沙KPM16 Shock Travel Sensor 长沙KPM18 Small Articulated Resistance Sensor 长沙KPM22 Small Articulated Resistance Sensor 长沙KPM23 Small Articulated Resistance Sensor 长沙KPM12 Shock Travel Sensor 长沙WY-01 Resistive Displacement Sensor_COPY 长沙WY-01 Resistive Displacement Sensor 长沙KSE Pull Rod Displacement Sensor 长沙KSC Square Tube Miniature Self-reset Displacement sensor 长沙KSP Circular Tube Miniature Self-reset 长沙KTR11/12,KTR2 Spring Self-return Position Potentiometer 长沙KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 长沙KSN Self-resetting Displacement Sensor 长沙KFM Micro Slider Type Resistance Sensor 长沙WDL Rod Type Displacement Sensor 长沙KPF Flange Displacement Sensor 长沙KTM Miniature Pull Rod Displacement Sensor 长沙KPFZ Flange-mounted self-resetting resistance ruler 长沙KSD Linear Position Sensor 13FLP 长沙KST Self resetting displacement sensor 长沙KS8X Micro Self-resetting Displacement Sensor 长沙KSE Rod type displacement sensor 长沙KPM9 Mini Type Pull Rod Displacement Sensor 长沙LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 长沙KEP Brushless Sensor with Waterproof and Dustproof 长沙LEP displacement sensorwith Waterproof and dustproof
more+

长沙The displacement sensor series for gate water conservancy engineering(can be customized)

more+

Rope/wire displacement sensor

长沙WS-S Pull Wire Displacement Sensor 长沙MPS-XL Pull Wire Displacement Sensor 长沙MPS-L Pull Wire Displacement Sensor 长沙MPS-L Magnetic Draw Wire Displacement Sensor 长沙MPSFS2-S Waterproof Absolute Wire Rope Sensor 长沙LPS-M Pull Wire Displacement Sensor 长沙LPS-S Pull Wire Displacement Sensor 长沙MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 长沙MPS-XS Magnetic Mounting Rope Displacement Sensor 长沙MPSFS2-M Waterproof Absolute Wire Rope Sensor 长沙MPS-XXXS Pull Wire Displacement Sensor 长沙MPS-XXS Pull Wire Displacement Sensor 长沙MPS-XS Pull Wire Displacement Sensor 长沙MPS-S Pull Wire Displacement Sensor 长沙MPS-M Pull Wire Displacement Sensor 长沙MDS-S Pull Wire Displacement Sensor 长沙SM-S Pull Wire Displacement Sensor 长沙WEP-S Pull Wire Displacement Sensor 长沙WEP-M Pull Wire Displacement Sensor 长沙SM-M Pull Wire Displacement Sensor 长沙MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 长沙MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 长沙MPSFS2-L Waterproof Absolute Wire Rope Sensor 长沙MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 长沙MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 长沙MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 长沙MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长沙MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长沙MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长沙MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长沙MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长沙MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
more+

Fixed inclinometer sensor

more+

长沙Spoke type weighing sensors《Special Customizable》

more+

长沙Three pulley tension sensor

more+

长沙Gap displacement sensor

more+

长沙Wireless data transmission radio/wireless transmission module

more+

长沙RS485 to USB converter

more+

长沙Wansung position sensor

more+

Digital Indicator

more+

长沙CH6 Displacement Display Instrument

more+

长沙XSA Digital Display Instrument

more+

长沙XSAW Potentiometer Digital Display Instrument

more+

长沙XSAEW Digital Display Instrument

more+

长沙XSEW Digital Display Instrument

more+

长沙XSK Digital Display Instrument

more+

长沙XSAE Displacement Sensor Digital Display Instrument

more+

长沙Fully Automatic Lubricating Oil Pump

Your current location is:Home>>长沙Product>>长沙Fully Automatic Lubricating Oil Pump>>长沙Electric Automatic Oil Pump / Manual Oil Pump

长沙MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump

  • Product classification:Electric Automatic Oil Pump / Manual Oil Pump
  • Number of views:587
  • QR code:
  • Release time:2023-11-14
  • Overview

MR-2232-3 (3L)      

Self-control Oil Lubrication Pump

米朗MR-2232-3 (3L) 稀油电动润滑油泵微电脑型3L


米朗MR-2232-3 (3L) 稀油电动润滑油泵微电脑型3L



Technical Parameters



Model


Voltage


Rated

ritary

Speed


Power


Current(A)


Rated pressure

kgf/cm²


Max pressure

kgf/cm²


Volume


Discharge

capacity ml/min


Rated

pressure

kgf/cm²


Remarks

MR-2232-300TAB

220V

50/60HZ

2400

18W

0.12

18

35

3L

150-200

CC/min

30-1000

MR-2231 refers to voltage 110V

MR-2232 refers to voltage 220V

MR-2232-300XAB

220V

50/60HZ

MR-2232-310XAB

220V

50/60HZ


*Mode name with " T" is resistant, mode name with “X” is volumetric,mode name with “A” is shade-pole motor


The wiring diagram


米朗MR-2232-3 (3L) 稀油电动润滑油泵微电脑型3L



Performance Characteristics

1.Fuel supply time is set by the UP button(extending the time) and DOWN button(shortening the time) on the right side of the control panel, which can reach up to 200 seconds, with the precision of 1 second. Intermittent time is set by the UP button(extending the time) and DOWN button(shortening the time) on the left side of the control panel, which can

reach up to 999 minutes, with the precision of 0.1 minute. When setting the time, the beat number is 1 if you press the button once. The beat number can be accelerated if you hold down the button. All the settings will take effect immediately after the setting is completed or after the Man button is pressed.

2.When the oil pump shows the EPR alarm, it indicates that the pressure is insufficient. If the the pressure is normal, press the Man button to eliminate the alarm.

3.When the oil pump shows the ERO alarm, the oil quantity is insufficient,and the alarm will be automatically eliminated after refueling .

4.Holding down the Man button is manual test.

(specific lubrication plan can be customized)



  • Application