TEL:

180 3818 6775

Announcement:

Product

昌都Sensors

more+

Linear Position Sensor

more+

昌都KTC11 Pull Rod Linear Displacement Sensor 昌都KTC1/LWHPull Rod Linear Displacement Sensor 昌都KTF Slider Displacement Sensor 昌都KTC2/KTC21 Pull Rod Linear Displacement Sensor 昌都KTF1 Slider Displacement Sensor 昌都KTR11/12,KTR2 Spring Self-return Position Potentiometer 昌都KTM Miniature Pull Rod Displacement Sensor 昌都KTR3/KTR4 Spring Self-return Position Potentiometer 昌都TR Spring Self-return Position Potentiometer 昌都KPC1H Hersman Plug out Pull-rod Resistance 昌都KPC1 Articulated Electronic Ruler 昌都KPM23 Small Articulated Resistance Sensor 昌都KPM22 Small Articulated Resistance Sensor 昌都KPM18 Small Articulated Resistance Sensor 昌都KPM16 Shock Travel Sensor 昌都KPM12 Shock Travel Sensor 昌都KPM12R1/KPM12R2 Self-reset Resistance Sensor 昌都WY-01 Resistive Displacement Sensor 昌都WDL Rod Type Displacement Sensor 昌都KSE Pull Rod Displacement Sensor 昌都KPF Flange Displacement Sensor 昌都KFM Micro Slider Type Resistance Sensor 昌都KSP Circular Tube Miniature Self-reset 昌都KSC Square Tube Miniature Self-reset Displacement sensor 昌都KS8X Micro Self-resetting Displacement Sensor 昌都KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 昌都KST Self resetting displacement sensor 昌都KSD Linear Position Sensor 13FLP 昌都KPFZ Flange-mounted self-resetting resistance ruler 昌都LEP displacement sensorwith Waterproof and dustproof 昌都KEP Brushless Sensor with Waterproof and Dustproof 昌都LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 昌都KPM9 Mini Type Pull Rod Displacement Sensor 昌都KSE Rod type displacement sensor 昌都KSF Micro Slide Type Displacement Sensor 昌都KSN Self-resetting Displacement Sensor
Rope/wire displacement sensor

more+

昌都MPS-XXXS Pull Wire Displacement Sensor 昌都MPS-XXS Pull Wire Displacement Sensor 昌都MPS-XS Pull Wire Displacement Sensor 昌都MPS-S Pull Wire Displacement Sensor 昌都MPS-M Pull Wire Displacement Sensor 昌都MPS-L Pull Wire Displacement Sensor 昌都MPS-XL Pull Wire Displacement Sensor 昌都MPSFS2-S Waterproof Absolute Wire Rope Sensor 昌都MPSFS2-M Waterproof Absolute Wire Rope Sensor 昌都MPSFS2-L Waterproof Absolute Wire Rope Sensor 昌都MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 昌都MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 昌都MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 昌都MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 昌都MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 昌都MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 昌都MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 昌都MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 昌都MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 昌都SM-S Pull Wire Displacement Sensor 昌都SM-M Pull Wire Displacement Sensor 昌都WEP-S Pull Wire Displacement Sensor 昌都WEP-M Pull Wire Displacement Sensor 昌都WS-S Pull Wire Displacement Sensor 昌都MDS-S Pull Wire Displacement Sensor 昌都MPS-XS Magnetic Mounting Rope Displacement Sensor 昌都MPS-L Magnetic Draw Wire Displacement Sensor 昌都MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 昌都MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 昌都MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor
Magnetostrictive displacement/liquid level sensor

more+

昌都Fully Automatic Lubricating Oil Pump

more+

昌都Electric Automatic Oil Pump / Manual Oil Pump

more+

昌都MIRAN MR-2202-2(2L) Thin Oil Lubrication Pump Controlled by PLC Type 昌都MIRAN MR-2232-2(2L) Self-control Electric Oil Lubrication Pump 昌都MIRAN MR-2202-3(3L) Thin Oil Electric Lubrication Pump 昌都MIRAN MR-2232-3(3L)Self-control Electric Oil Lubrication Pump 昌都MIRAN MRG-2202(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 昌都MIRAN MRG-2232(4L) Asynchronous Dynamo Grease and Thin Oil Lubrication Intergrated Pump 昌都MIRAN MRG-3202(5L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 昌都MGH-1205-100T Semi-automatic Butter Lubrication Pump 昌都MIRAN MRG-3205(5L) Grease and Thin Oil Intergratd Pump by PLC Type 昌都MIRAN MRG-3232(5L)Grease and Thin Oil Lubrication Intergrated Pump 昌都MRG-3202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 昌都MIRAN MRG-3235(5L) Grease and Thin Oil Lubrication Electric Intergrated Pump 昌都MRG-3232(3L) Self-control Grease and Thin Oil Lubrication Pump 昌都MIRAN MRG-5202(3L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 昌都MRG-5232-41 Self-control Grease and Thin Oil Lubrication Pump 昌都MIRAN MRG-5202-41 (4L) Grease and Thin Oil Lubrication Intergrated Pump by PLC Type 昌都MRG-5202(5L) Self-control Grease and Thin Oil Lubrication Pump with PLC Type 昌都MRG-5232(5L) Self-control Grease and Thin Oil Lubrication Pump 昌都MRH-1202-100T Semi-automatic Grease Lubrication Pump 昌都MRH-1232-100TB Automatical Grease Lubrication Pump 昌都MGH-1202-100T Semi-automatic Butter Lubrication Pump 昌都MGH-1232-100TB Self-control Butter Pump
Your current location is:Home>>昌都Product>>Digital Indicator>>昌都XSK Digital Display Instrument

昌都XSK Digital Instrument

  • Product classification:XSK Digital Display Instrument
  • Number of views:1872
  • QR code:
  • Release time:2023-11-14
  • Overview

XSK Digital Display Instrument

0.2 level accuracy, measurement and control speed can be set to 10 or 40 times per second,display range -1999~9999.
Dual four-digit digital tube display (main display + second display), of which the second display can display engineering quantity units, alarm values and other information.
Universal input, selected by setting up.
Optional 1 to 4 points alarm output. 7 basic alarm modes and 4 standby alarm modes: upper limit of standby, lower limit of standby, upper limit of standby deviation, and lower limit of standby deviation. (Standby alarm mode: means that when the instrument is powered on, it does not alarm when the measured value is in the output range. When the measured value enters the non-output range, a standby condition is established, and then the alarm is normal).
10-section polyline correction function.
1 point external switch input, used for clearing.
 Peak and valley value acquisition function.
Communication and transmission are optional.

content

Code description

XSK-

Universal analog input, 0.2 level display accuracy; measurement and control speed can be set to 10 or 40 times per second

Dimension

AH

160×80×125      Hole Size:152×76      (Note①)

AS

80×160×125       Hole Size:152×76   (Note①)

 

B

96×96×76       Hole Size:92×92      (Note②)

 

CH

96×48×82       Hole Size:92×45      (Note③)

 

CS

48×96×82       Hole Size:92×45      (Note③)

 

D

72×72×75       Hole Size:68×68      (Note④)

 

E

48×48×88       Hole Size:45.5×45.5  (Note⑤)

 

Panel specifications


Dual 4-digit LED display

Contact input (optional)

K

1 point external switch input for zeroing.(When AH and CH select K, communication and transmission can only choose one option; E size does not support K option)

Alarm(option)(250V AC/3A,resistive load)

A

T1~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

B

 

T1~T2

1~2 point relay output, are normally open and closed double contacts

 

T3~T4

1~4 point relay output, are normally open and closed double contacts

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

C

T1~T2

The output of 1~2 point alarm relay is normally open and closed double contacts

T3

The output of 3 alarm relay is single open contact

T3R

The output of the 3-point alarm relay is normally open and closed double contacts

T4

4 points alarm relay output, the first 3 points are single normally open contact, the fourth point is normally open normally closed double contact

O1~O4

1-4 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

D

T1~T2

1~2 point alarm relay output, 1 often open and close double contact; 1 often open contact

T3

3 points of alarm relay output, 1 point is normally open and normally closed double contact, and another 2 points are single and normally open contact

O1~O3

1-3 point OC gate output (voltage should be less than 40VDC and current should be less than 40 mA

E

T1~T2

1~2 point alarm relay output, 1 point often open often closed contact, the other point is normally open contact

O1~O2

1-2 point OC gate output (voltage shall be less than 40VDC and current shall be less than 40 mA)

Transmitting (optional)

(resolution: 1/3000; load capacity: 600Ω)

A1

Current output(4-20)mA、(0-10)mA、(0-20)mA

A2

Voltage output(1-5)V、(0-5)V

A3

Voltage output(0-10)V

A4

Voltage output(-5V-+5V)

A5

Voltage output(-10V-+10V)

External power supply (optional)

B1

24V±5% 50mA below

B2

12V±5% 50mA below

B3

10V±5% 50mA below

Communication (option) (the communication protocol is optional through the instrument parameters: Modbus-RTU or TC-ASCII protocol)

S1

The RS232 interface(only AH AS B size)

S2

The RS485 interface

Power Specifications

V0

100-240V AC 50/60 Hz

V1

10-24VAC 50/60Hz;10-24VDC 

Note : A size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note : B size instrument

When selecting 1-point switching input, the instruments transmission output and communication functions can only be selected from one of the two.

Note :C size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3R or T4 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected one of the two, and communication can only select RS485 mode (i.e. S2)

Note : D size instrument

When selecting an external power supply, you can only choose one of the three switch input, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When selecting 1-point switch input, you can only choose one of the three external supply output, transmission output and communication functions of the instrument (at this time, communication only supports RS485)

When T3 is selected for alarm, external power supply cannot be selected; transmission output and communication can only be selected from one of the two, and communication can only select RS485 mode (i.e. S2)

Note : E size instrument

You can choose two out of three for 1-point switching input, transmission output and communication functions (communication only supports RS485 at this time)

When 2-point alarm output is selected2, external power supply cannot be selected; 1-point switching input, transmission output and communication functions can be selected two out of three (communication only supports RS485 at this time)