TEL:

189 8877 5298

Announcement:

Product

长春Sensors

more+

Linear Position Sensor

more+

长春KTC1/LWHPull Rod Linear Displacement Sensor 长春KTC2 Pull Rod Linear Displacement Sensor 长春KTF Slider Displacement Sensor 长春KTF1 Slider Displacement Sensor 长春KPC1 Articulated Electronic Ruler 长春KPC1H Hersman Plug out Pull-rod Resistance 长春KPM12R1/KPM12R2 Self-reset Resistance Sensor 长春KPM16 Shock Travel Sensor 长春KPM18 Small Articulated Resistance Sensor 长春KPM22 Small Articulated Resistance Sensor 长春KPM23 Small Articulated Resistance Sensor 长春KPM12 Shock Travel Sensor 长春WY-01 Resistive Displacement Sensor_COPY 长春WY-01 Resistive Displacement Sensor 长春KSE Pull Rod Displacement Sensor 长春KSC Square Tube Miniature Self-reset Displacement sensor 长春KSP Circular Tube Miniature Self-reset 长春KTR11/12,KTR2 Spring Self-return Position Potentiometer 长春KS8 S8FLP10A,5k Mini Type Linear Position Micro Self-resetting Displacement Sensor 长春KSN Self-resetting Displacement Sensor 长春KFM Micro Slider Type Resistance Sensor 长春WDL Rod Type Displacement Sensor 长春KPF Flange Displacement Sensor 长春KTM Miniature Pull Rod Displacement Sensor 长春KPFZ Flange-mounted self-resetting resistance ruler 长春KSD Linear Position Sensor 13FLP 长春KST Self resetting displacement sensor 长春KS8X Micro Self-resetting Displacement Sensor 长春KSE Rod type displacement sensor 长春KPM9 Mini Type Pull Rod Displacement Sensor 长春LEPF Brushless Sensor with Waterproof and Dustproof(Stroke can be customized) 长春KEP Brushless Sensor with Waterproof and Dustproof 长春LEP displacement sensorwith Waterproof and dustproof
Rope/wire displacement sensor

more+

长春WS-S Pull Wire Displacement Sensor 长春MPS-XL Pull Wire Displacement Sensor 长春MPS-L Pull Wire Displacement Sensor 长春MPS-L Magnetic Draw Wire Displacement Sensor 长春MPSFS2-S Waterproof Absolute Wire Rope Sensor 长春LPS-M Pull Wire Displacement Sensor 长春LPS-S Pull Wire Displacement Sensor 长春MPS-M Plastic Protective Cover Pull Wire Displacement Sensor 长春MPS-XS Magnetic Mounting Rope Displacement Sensor 长春MPSFS2-M Waterproof Absolute Wire Rope Sensor 长春MPS-XXXS Pull Wire Displacement Sensor 长春MPS-XXS Pull Wire Displacement Sensor 长春MPS-XS Pull Wire Displacement Sensor 长春MPS-S Pull Wire Displacement Sensor 长春MPS-M Pull Wire Displacement Sensor 长春MDS-S Pull Wire Displacement Sensor 长春SM-S Pull Wire Displacement Sensor 长春WEP-S Pull Wire Displacement Sensor 长春WEP-M Pull Wire Displacement Sensor 长春SM-M Pull Wire Displacement Sensor 长春MPS-M Aluminum Alloy Protective Cover Pull Wire Displacement Sensor 长春MPS-M Stainless Steel Protective Cover Pull Wire Displacement Sensor 长春MPSFS2-L Waterproof Absolute Wire Rope Sensor 长春MFB-MPSFS2-S Waterproof and Explosion-proof Type Wire Rod Sensor 长春MFB-MPSFS2-M Waterproof and Explosion-proof Type Wire Rod Sensor 长春MFB-MPSFS2-L Waterproof and Explosion-proof Type Wire Rod Sensor 长春MBA-MPS-XXXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长春MBA-MPS-XXS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长春MBA-MPS-XS Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长春MBA-MPS-S Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长春MBA-MPS-M Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor 长春MBA-MPS-L Intrinsically Safe Explosion-proof Pull Wire Displacement Sensor
长春Fully Automatic Lubricating Oil Pump

more+

Your current location is:Home>>长春Product>>长春Sensors>>长春LVDT differential transformer displacement sensor

长春Inductive frequency modulation displacement sensor

  • Product classification:LVDT differential transformer displacement sensor
  • Number of views:654
  • QR code:
  • Release time:2024-01-08
  • Overview

ML-F-50MM Inductive frequency modulation displacement sensor:


Application areas: Used on static load testers, in nuclear explosion tests, in geotechnical and in-situ testing, and in industrial and other fields.

         

Inductive frequency modulation displacement sensors can be widely used in national defense engineering scientific experiments, engineering survey and design geotechnical tests, and in-situ testing in various industries and industrial automation and measurement and control technology fields. Becoming an ideal choice for intelligent secondary instruments and supporting products in the microcomputer application department.

The inductive frequency modulation displacement sensor has excellent performance, using a convenient single power supply of 12V DC. The electronic circuit is sealed in a 304 stainless steel metal tube, and has waterproof, anti-corrosion, and explosion-proof properties.

电感调频式位移传感器



          

Characteristics of ML-F Inductive Frequency Modulation Displacement Sensor:

1. Outer diameter Φ 21mm, stainless steel 304 shell, rebound type.

2. Accurate detection: The repeatability and return error are very small, with errors less than 0.05%; The nonlinear error ranges from 0.1% to 1.0%. 3. Remote transmission does not affect testing accuracy and has high resolution.

4. Reliable in operation, due to its simple and compact structure, tight packaging, earthquake resistance and moisture resistance, it is particularly suitable for use in harsh environments.

5. Stable performance. Save power and cables


Technical parameters :


Stroke Length

50mm,100mm

Output Signal

Square wave signal with amplitude greater than 2V

Resolution

≤0.01MM

Linearity Error

0.1%---1.0%

Power Supply

12V DC

Working Current

≤5mA

Shock Resistance

250g/11ms

Vibration Tolerance

10g/2KHZ

Center frequency

16KHZ ±4%

Temperature Coefficient

Zero Point≤0.01%/℃

Allow cable length

≤1000 Meter

Operation temperature

-25℃~+85℃



Instructions for use:

1. Voltage and signal waveform: Power supply is 12V DC, square wave signal output

2. Installation: The sensor is fixed with a dial gauge holder or a magnetic gauge holder

3. Wiring: The sensor wire is a two core microphone wire, shielded as a ground wire, connected to the low terminal of the power and signal. One core wire is connected to the positive pole of the power supply, and the other is connected to the signal input terminal. The plug outputs, with one pin connected to the signal, two pins connected to the power supply, and three and four pins connected to the ground

4. The reading should be taken 30 minutes after power on

5. The factory comes with a 5-meter cable. If it is not enough, it should be declared in advance for extension

6. Properly protect, prevent falling, and strictly use according to technical conditions


Mechanical installation dimensions :



电感调频式位移传感器



Miran displacement sensor calibration table

Sensor model: ML-F-50MM

① Within the range of -10~50 ℃, the average frequency drift per degree is 0.1Hz/℃

② Frequency drift of 1Hz for 4 hours at room temperature of 20 ℃

③ Rating Results Table



1704878689892186.png

  • Application